Lisun Electronics Inc.
Lisun Electronics Inc was found by Lisun Group in 2003. We have sales & service offices in Shanghai, Russia, India and Korea. In 2012, we built a high level products show room & lab center in Shanghai. Lisun Group has set up a new manufactory in China to research and develop the world high-technology CFL & LED Test Instruments. Its quality system has been strictly certified by ISO9001:2008. The Lisun Group products have been authenticated by the third party lab and were awarded by CE certificate. As a CIE Supportive Member, all of the test instruments produced by Lisun Group are designed according to CIE Standards.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
product
Car Accessories Material Burning Tester
ZRS-4H
• Test Gas Source: Gas or Liquefied Petroleum Gas (Suggestion: Use good quality gas if possible) • Burner inner diameter: ¢9.5±0.5mm, about 100mm long with air adjusting hole • Height of flame: Can be adjusted from 20 mm to 100 mm according to the standard requirement • Applying time of flame: Burning time can be adjusted from 0 to 99 minutes 99 seconds • Test process: Automatic control • Inner volume: 0.05m³ • Material: Stainless steel or iron plate spray • Power: AC 220V; 50Hz/5A
-
product
Constant Temperature Integrating Sphere
IS-*MT
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Photometer
PH2000
• Flux or Lumen measure range depends on the size of the integrating sphere • Light current measuring range: 0.005×10-7A~2000×10-7A • User can do ZERO and Calibrate by operating the keys on the front of panel • Photo Detector: Class 1 • High correcting accuracy of photo detector V(λ) • English Software can be run in WinXP or Win7 by RS-232 (option)
-
product
AC and DC Power Supply
The DC Series Power Supplies are with high stability and high accuracy. The voltage and current can be adjustable and simple operation. They are suitable to supply DC Power for the standard lamp and the large power LED. Other voltage and current DC Power Supply can be designed according to customer's request.
-
product
Pocket Illuminance Meter
PHOTO-100
This Pocket Illuminance Meter has performance of high precision, low consumption, small volume, stable performance and convenience operation. It’s mainly used in industrial field for illumination photometry.
-
product
LM-79 Moving Detector Goniophotometer
LSG-5000
Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
-
product
Electronic Transformer Test System
UI2000-ET
• Input characteristics analysis 1) Measure Vrms (10-300V) Lrms (0.04-4A) W, PF, Hz, total harmonic and 0-50 component of harmonic 2) Accuracy: ± (0.4%reading + 0.1%range + 1digit) • Output characteristics analysis 1) Measure lamp voltage (1-60V) lamp current (03-20A) lamp power, crest factor and oscillatory frequency 2) Accuracy: Class 2 • It can print without compute, and provide the communication port for PC
-
product
Rotation Luminaire Goniophotometer
LSG-1800
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Temperature Rise Tester
WS-1
Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right. It is designed and manufactured according to IEC884-1, GB2099.1-2008 and other relevant standard of electrical accessories.
-
product
Electronic Ballast High Frequency Parameters Tester
UI2002A
• Measure Vrms, Irms, W, PF/Hz • Voltage range: 10~600V, Current range: 10~2000mA, Frequency range: 20~70kHz • Accuracy: Class 2
-
product
Photometer and Colorimeter
Illuminance (lux), CCT, Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram
-
product
High Precision Spectroradiometer Integrating Sphere System
LPCE-2(LMS-9000)
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
-
product
Magnetic Shielding Cabinet for EMI Testing
SDR-2000B
Cabinet Shell 2mm galvanized cold-rolled steel sheetCabinet Door 0.9*1.7m(L*W) 0.6*0.6mCabinet Window 0.3*0.3*0.025m(L*W*T) with 4mm hole N/APower Supply Filter 30A/220V 30A/220VInternet Line Filter RJ-45 N/ACabinet Inside Decoration PVC ceiling, PVC plastic steel wall, 10mm wooden + 2mm galvanized steel sheet floorCabinet Inside Size 2*1.2*1.8m 0.8*0.8*0.8mAfter Packing Size 2.2*2.3*2.3m 1*1.1*1.2mAfter Packing Weight 800kg 200kgWorking With EMI-9KA/EMI-9KB EMI-9KA/EMI-9KB, PC, Testing load, and operator inside Testing load is inside to connect with EMI-9KA/EMI-9KB via BNC
-
product
Mask Produce and Test Machine
LISUN produce the bfe tester for face mask, pfe tester, melt-blown cloth electrostatic electret generator according to ASTM F1862-17, ASTM F2299-03 (2017), ASTM F2100-2019, BS EN14683-2019, BS EN 14387-2004+A1 2008, BS EN 136-1998, BS EN 140-1999, BS EN 143-2000 +C1-A1, BS EN 149-2001+A1
-
product
Portable CCD Spectroradiometer
LMS-6000
The Portable CCD Colorimeter Spectroradiometer has the following versions which can measure different parameters: • LMS-6000: illuminance (lux), E(Fc), Ee(W/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000L: cd/m2, fL, Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000P: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio • LMS-6000S: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio, Rf and Rg according to TM-30 • LMS-6000F: LMS-6000 Parameters+Flicker test • LMS-6000B: LMS-6000 Parameters+Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002 • LMS-6000BF: LMS-6000 Parameters+Flicker test, Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002