Physitemp Instruments
Physitemp Instruments Inc is an electrical/electronic manufacturing company.
- 800.452.8510
973.779.5577 - 189 Sargeant Avenue
Clifton, NJ 07013
United States
-
product
Air And Gas Probe
GT-1
GT-1 Air and Gas Probe - 24'' #304 stainless steel shaft. Wooden Handle. For instant readings of temperature gradients in environmental chambers, freezer boxes, etc. Diameter is .3/16'' diameter. Immersible. Maximum temperature 200°C, Time constant Seconds. 5 foot lead. Not isolated.
-
product
Animal Temperature Control
TCAT-2AC
This version controls only AC powered heating or cooling devices such as a heat lamp. It is the least costly.
-
product
Animal Temperature Controller- Dual Feature
TCAT-2DF
This is a combination version which includes both and AC outlet for controlling primarily resistance loads such as heat lamps, AC powered warming blankets and a low-voltage, low noise DC output for heating pads. This version allows you to controls a variety of different loads.
-
product
Animal Temperature Controller - Low Voltage
TCAT-2LV
Our TCAT-2 family of general purpose PID Autotuning Controllers provides accurate temperature control in a variety of laboratory applications. Combined with a heat lamp or heating pad, the TCAT-2 may be used to maintain the body temperature of anesthetized animals during surgery or stereotaxic procedures. Small animal cages are easily warmed with a heat lamp. The TCAT-2 may also be used in cooling applications, such as to control independent perfusate cooling systems. Realizing that laboratory applications are diverse, Physitemp can provide several versions of the TCAT Controller. The model specified depends on whether a laboratory has a general or specific need for the controller
-
product
Esophageal Probe
ESO-1
The ESO-1 Esophageal/Rectal Probe for humans and larger animals. Flexible vinyl covered, soft tipped. 5 foot lead (can be made longer), 7/32'' max. tip diameter, lead diameter 1/8''. Time constant 5.0 seconds.
-
product
Flexible Implantable Microprobe
IT-18(10 FOOT)
IT-18(10 FOOT) Flexible Implantable Microprobe with 5 foot lead - Implantable in semi-solids and tissue with 18 gauge needle (supplied). Also for immersion in various solutions and rectal temperatures of small animals. Totally sheathed in chemical resistant Teflon™. Quited rugged. Maximum Temperature 150°C . Isolated. Probe diameter .050" (14 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.3 seconds.
-
product
Flexible Implantable Microprobe
IT-18
IT-18 Flexible Implantable Microprobe - Implantable in semi-solids and tissue with 18 gauge needle (supplied). Also for immersion in various solutions and rectal temperatures of small animals. Totally sheathed in chemical resistant Teflon™. Quited rugged. Maximum Temperature 150°C . Isolated. Probe diameter .050" (14 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.3 seconds.
-
product
Flexible Implantable Microprobe
IT-1E
IT-1E Flexible Implantable Microprobe - For ultra fast measurements and for use on micro-size specimens. Similar to our most popular IT-18 microprobe but the sensor bead is exposed, resulting in the same ultra-fast response time of the IT-23 but with the Teflon™ sheath strength of the IT-18. Time constant 0.005 seconds. Tissue Implantable with a 18 gauge needle (supplied). Rather fragile at tip. Coated in Teflon™. Maximum Temperature 150°C. Isolated. Probe tip diameter .011", sheath diameter .025'' . 3 foot lead.
-
product
Flexible Implantable Microprobe
IT-14
IT-14 Flexible Implantable Microprobe - Implantable in semi-solids and tissue with 14 gauge needle (supplied). Also for immersion in various solutions. Totally sheathed in chemical resistant Teflon™. Quited rugged. Maximum Temperature 150°C . Isolated. Probe diameter .050" (14 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.3 seconds.
-
product
Flexible Implantable Microprobe
IT-18EXLONG
IT-18EXLONG Flexible Implantable Microprobe with 5 foot lead - Implantable in semi-solids and tissue with 18 gauge needle (supplied). Also for immersion in various solutions and rectal temperatures of small animals. Totally sheathed in chemical resistant Teflon™. Quited rugged. Maximum Temperature 150°C . Isolated. Probe diameter .050" (14 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.3 seconds.
-
product
Flexible Implantable Microprobe
IT-21
IT-121 Flexible Implantable Microprobe - Implantable in semi-solids and tissue with 21 gauge needle (supplied). Ideal for subcutaneous and cranial temperatures in small animals. Also for immersion in various solutions. Totally sheathed in chemical resistant Teflon™. Maximum Temperature 150°C . Isolated. Probe diameter .016" (21 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.08 seconds.
-
product
Flexible Multisensor Probes
IT Series
Physitemp multisensors are made with our specially manufactured thermocouple wire. We test and grade this wire to standards better than the accepted ''Special Limits of Error'' and guarantee 0.1°C accuracy in the range of 0-50°C . All multisensor probes conform to NIST standards. These multisensor probes are custom-made and should be ordered to your requirements on number of sensors and spacing between sensors.
-
product
Foot Rest
VFR-1
The optional footrest is designed to be used with the Vibratron-II. The foot rest is 12'' long x 8'' wide x 4.25'' high with adjustable non-slip leveling feet ( feet are adjustable to add up to 1/2'' of additional height if needed). Surface of the footrest is a white hygienic non-skid vinyl covering and can be easily cleaned between uses. The unit is large enough to accommodate both feet and may also be used as an armrest when testing upper extremities. The weight of the unit is approximately 4.5 pounds. The footrest can also be purchased as an option to the NTE-2A .
-
product
Gauge Type T Thermocouple Wire
W-TW-40P
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
product
Gauge Type T Thermocouple Wire
W-TW-24
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.