APPLIED IMAGE Inc. is a world leader in the design and manufacture of precision-imaged optical components intended for a wide range of applications and industries that require NIST-traceable standards and/or precision-imaged components to test, calibrate, align, control or measure their optical or photonics systems. In addition to its large catalog of standard products, APPLIED IMAGE specializes in designing and manufacturing custom components, imaged to the strictest tolerances. Its mission is to provide the highest-quality products and customer service to consistently meet and exceed the expectations of its customers such as NASA (Mars Rover) and Goddard (International Space Station).
- (585) 482-0300
- (585) 288-5989
- 1653 East Main Street
Rochester, NY 14609
United States
-
product
ACCUplace BullsEye /Recognition Grid
AP-B Series
A unique concept in imaging calibration technology, The ACCUplace Bulls Eye / Recognition Grid allows the end user to calibrate magnification at multiple power levels, as well as test the system’s ability to recognize and locate distinctive shapes within shapes by focusing on the concentric circles.Each Bulls Eye / Recognition Grid target has individual patterns consisting of 5 concentric circles with 0.50mm line width and 0.50mm spacing between circles (10mm Pitch) with a 0.100mm center dot. In addition, each row and column is labeled with X & Y coordinates. The AP-B series is offered on four standard substrates; Chrome on Glass (CG) Opal (OP) Photopaper (RM) and Film (TM).
-
product
ACCUplace Dot Distortion Target
AP-DD Series
All machine vision lenses will show some type of distortion. Minimizing or correcting that distortion is crucial in most applications. The ACCUplace Dot Distortion target is designed to detect the presence of both barrel/pincushion distortion as well as alignment distortion that causes the keystone effect. The precise amount of distortion is determined from an array of precisely placed dots in a regular array. The results can be used to correct for any distortion that occurs within the optical system. The AP-DD is offered on three standard substrates; Chrome on Glass (CG) Opal (OP) and Photo Paper (RM).
-
product
ACCUplace Dot Patterns
AP-D Series
All machine vision lenses will show some type of distortion. Minimizing or correcting that distortion is crucial in most applications. The ACCUplace Dot Patterns target is designed to check, verify, or quantify barrel distortion in vision systems, alignment between multiple optical systems, and can calibrate instruments with both vision and motion systems. The indexed columns and rows of dot features provide reference points that make alignment and distortion detection simple and straightforward. The AP-D is offered on four standard materials; Glass (CG) Opal (OP) Photopaper (RM) and Film (TM).
-
product
ACCUplace Grid Indexing Pattern
AP-G Series
Ensuring precise motion and positional accuracy is critical for a number of video analysis systems and automated measuring instruments. The AP-G series is ideally suited for calibrating such elements, in addition to its uses in determining stage squareness, and travel distance image analysis and visual inspection systems where precise motion must be calibrated and measured. All AP-G targets have number/letter indexed columns and rows for easy calibration and are offered on four standard materials; Glass (CG) Opal (OP) Photopaper (RM) and Film (TM).
-
product
ACCUplace Land Pattern Kit
APKIT-1
APPLIED IMAGE, in conjunction with Hewlett Packard Corp., has developed a unique, and extremely accurate, pick & place target set designed to check for accuracy and repeatability of your robotic system quickly and easily.
-
product
ACCUplace Land Pattern Plate
APLP-1
APPLIED IMAGE, in conjunction with Hewlett Packard Corp., has developed a unique, and extremely accurate, pick & place target set designed to check for accuracy and repeatability of your robotic system, quickly and easily.
-
product
ACCUplace Macro Calibration Standard
AP-M Series
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
product
ACCUplace Position Grid
AP-P Series
The AP-P is a unique calibration target that is designed to test the position and/or recognition ability of a vision system. The matrix of small scales, precisely positioned in a grid matrix format, makes testing for subject recognition and system positioning simple.The overall target is comprised of a matrix consisting of 6.0mm x 6.0mm square individual components each having a 5.0mm x 5.0mm X & Y Scale with 0.100 divisions. The scale has pitch accuracy of 1μm. The AP-P is available on two standard materials; Chrome on Glass (CG) and Chrome on Opal (OP).
-
product
AIIM Test Charts (Scanner/Microfilm/Digital/ Copier)
AIIM Test Charts (Scanner/Microfilm/Digital/ Copier) by Applied Image - Motion-Rotary Target, Planetary-Static Target, Small Area Target/AIIM MS-303-1980, Small Scanner Resolution Target , Copier Test Array, Rotary Test Target/AIIM X113, Film Strip Target, Eastman Kodak Copier/Scanner Digital Test Target, Small Color MTF Target
-
product
Barcode Conformance Calibration Standards
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
product
Conformance Calibration Standard Test Card for GS1-DataBar Symbol Verifiers
AI-CCS-DATABAR
This test card is ideal for testing verifiers, scanners, and other GS1-DataBar barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
product
Conformance Calibration Standard Test Card for ITF-14 (Interleaved 2 of 5) Symbol Verifiers
AI-CCS-ITF-14
This test card is ideal for testing verifiers, scanners, and other ITF-14 (Interleaved 2 of 5) barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.