Laplace Instruments Ltd.
The Laplace products are designed and manufactured in he UK, we enable manufacturers to reduce the cost of EMC Testing, increase productivity and reduce the product time to market.
- +44 (0) 16 92 40 20 70
- tech@laplace.co.uk
- Tudor House
Grammar School Road
North Walsham, Norfolk NR28 9JH
United Kingdom
-
product
Harmonics & Flicker Analyser
AC2000A
The Laplace Harmonics and Flicker analyser provides the user with a complete system for testing product compliance with IEC61000-3-2 and IEC61000-3-3. Quick and easy to use, the built-in screen provides a clear pass/fail indication of compliance status, plus a full listing of results for each harmonic, in either tabular of bargraph format. The instrument is properly configured to cope with fluctuating harmonics. The Flicker mode provides proper measurement of short term and long term parameters, using algorithms specified in IEC61000-4-15. In addition, inrush current measurements can be automated such that the product under test can be automatically cycled on/off with user entered time profiles.
-
product
LETIS
Power amplifiers that are universally used for radiated immunity testing either cover the range below 1GHz or the range above 1GHz. This means that if the test requirement extends both sides of this 1GHz point, the power amplifier needs to be changed over. Genrally, this involves three connections... The LETIS handles all these connections automatically. Each is switched via a high performance RF relay under the control of a USB interface. Software issued with the Laplace Synthesisers automatically detects the presence of a LETIS and handles the switching automatically.
-
product
Near Field Probe Set
RF100
The RF100 probe set consists of a passive E field probe and H field probe, BNC adaptor and carry case. The output is via a BNC socket. These are general purpose probes which are ideal for use in conjunction with an EMC measuring system. They are sensitive to sources in close proximity, but are insensitive to background signals. This makes them ideal for the identification of emission frequencies in noisy environments... thus making measurements easier and quicker. The proximity requirement also enables sources to be located and the exit route identified.
-
product
Ophir Power Amplifiers
Ophir RF power amplifiers are rugged and reliable. They are available as complete rack mounted units incorporating power supply, fans and heatsinks, or as compact modules requiring a DC supply. Fans and/or heatsinks can be included if required.
-
product
Ancillaries.. Conducted
The ease and effectiveness of conducted emission measurements can be enhanced by the use of appropriate filters. In particular, broadband noise below the frequencies of interest can cause limiting (compression) in spectrum analysers, distorting the measurements.
-
product
Ancillaries - Radiated
EMC emissions can be at very low signal levels and pre-amplifiers can help to improve S/N ratio. The low level of emission signals can make them difficult to identify in noisy environments. RF filters are designed to attenuate the major sources of noise, thus making the task of measurement easier.
-
product
Antennas for EMC testing
The Laplace antennas cover 3 main groups...*Conventional log periodic types for OATS applications.*Miniature antennas for chamber and small enclosure applications.*Large loop antenna for EN55015 compliance testing.
-
product
CDNs
In addition to a range of 'conventional' CDNs, Laplace are unique in offering two other types. Both types are 'versatile' in that they are configurable, offering great flexibility in terms of the type of cable each model can be used with. This reduces the number of CDNs necessary to hold in stock. The final type is, in addition to being versatile, fitted with an output which monitors the RF level applied to the cable.
-
product
Clean Power Source
AC1000A
The AC1000 achieves its unique price/performance ratio by actively adjusting the incoming mains waveform to produce a clean output. Other suppliers use convertor techniques to completely recreate the output from scratch. Our solution delivers an output which achieves the required THD with the minimum of hardware and expense. It includes the ability to switch the correction in or out so that the original waveform can be observed and measured if required. Overload and thermal protection systems are built-in and produce an audible warning if activated.
-
product
Emissions Reference Source
ERS
The ERS is a comb generator that radiates RF continuously every 2MHz over the range 30MHz - 1000MHz. Each 2MHz peak is precisely measured during the calibration process with the ERS orientated both vertically and horizontally. These measurements are correlated against a 3m OATS such that any fully implemented CISPR16 site, measuring at 3m and using height scanning, will read the same.
-
product
ESD Test Simulator
ONYX16
The ONYX is a state of the art electrostatic discharge simulator available in 16kV or 30kV versions. It is the most ergonomic 30kV ESD gun without an additional base control unit that can be battery or mains operated. The easy to use touch screen, ergonomic design, modular RC units, multilingual interface, remote control software, built-in LED light and temperature & humidity display allows for trouble-free use of the ONYX in all types of test sites.
-
product
FaulTracker
FTR
The FTR Faultracker is a compact recording device which can be connected to up to 16 points in an electrical system. Any voltage from 12v to 240v can be connected. The FTR monitors the on/off status of each input. Any voltage above 6v is considered to be ON. An LED indicator on the front panel shows the status of each input. When set to logging, the FTR will log any and all 'events'. An event being the change of status of any input. Each event is logged strictly in the order it occurred with a date/time stamp. When logging is completed, the events can be stepped through one at a time so that cause/effect sequences can be analysed.
-
product
Filter Design System - Mode Analyser
EA-300
The EA-300 is a stand alone unit with internal firmware and a large colour display. It connects to the outputs from a standard LISN and feeds the results to any standard EMC analyser or receiver. The EA-300 prompts the user through the steps necessary to fully characterise the emissions from the EUT, then will output via the screen the recommended filter component values that would reduce these emissions to acceptable levels.
-
product
Source of Signals
CRS+
The CRS+ is a stable and calibrated source of signals which cover the 9KHz - 30MHz frequency range. The fundamental signal is a 15KHz comb and each harmonic is output as a narrowband peak of known amplitude. This signal is output on either the L and N lines, referenced to ground. A switch provides on/off and line selection.
-
product
Test Cells (
LaplaCell
LaplaCells provide a facility for the rapid and efficient testing of the EMC compliance of products. These cells offer a calibrated and screened environment in which radiated emissions can be measured and immunity to RF radiation can be tested. They \re calibrated according to the methodology of IEC61000-4-20, thus affording compliant testing to IEC61000-4-3 and pre-compliance testing for radiated emission testing.