Hilkar
Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkey
-
product
Explosion-Proof Heaters
Explosion-Proof Heaters (ATEX certified) provide neutral convection solutions of heating for electrical equipments in hazardous industrial locations where potential for explosion exists due to the presence of flammable gases, vapors, powder-metals or dusts.
-
product
LV Iron Core Shunt Reactors
Iron core Shunt Reactors act as an absorber of reactive power to increase energy efficiency of the power system. Shunt Reactors are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. Shunt Reactors can be directly connected to the power line or to a tertiary winding of a three-winding power or distribution transformer.
-
product
Air Core Electric Arc Furnace Reactors
Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.
-
product
Air Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
Generator Neutral Grounding & Leads Cubicles
Generator Neutral Grounding Cubicles are designed to minimize fault damage incurred by generators, maintain sufficient fault detection and improve power system reliability. Generator Neutral Grounding and Lead Cubicles are manufactured as for IEEE or IEC standards.
-
product
Air Core Neutral Grounding Reactors
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
product
Radiator Mounted Load Banks
RD-Series
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
product
Motor Starting Auto-Transformers
Motor Starting Auto-Transformers reduce the inrush current by stepping down the applied voltage during the start-up operation of induction and synchronous motors.
-
product
Air Core Harmonic Filter Reactors
Use of nonlinear loads such as power electronics based equipment and electric furnaces have been on the rise for the last decades. Such loads decrease the power quality of the network that they are connected to. One of the most important parameters for defining the power quality is harmonic distortion.
-
product
Sine Filters
Sine Wave Output Filter Modules provide satisfactorily smoothed sinusoidal waveform with low residual ripple form square waveform with high voltage spikes, present at the output of motor drives.
-
product
LV Iron Core Smoothing Reactors
Smoothing Reactors are serially connected reactors inserted in DC systems to reduce harmonic currents and transient over currents and/or current ripples in DC systems. They are necessary in order to smooth the direct current wave shape to reduce losses and improve system performance.
-
product
PLC Line Traps
Line Traps are used in transmission and distribution networks and they are the key components in Power Line Carrier (PLC) systems used for remote control signals, voice communication, remote metering and control between substations in the electrical T&D networks.
-
product
High Resistance Neutral Grounding Devices
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
product
LV Iron Core Harmonic Filters
Nonlinear loads such as power electronics based equipment and electric furnaces are sources of harmonic currents leading to harmonic distortion, which is one of the most important parameters for defining the power quality. Most of the commercial loads such as personal computers, photocopy machines, power supplies, and compact fluorescent lamps; and industrial loads such as AC and DC motor drives inject harmonic currents into the network that they are connected to.
-
product
Air Core Smoothing Reactors
Smoothing Reactors are serially connected reactors inserted in DC systems to reduce harmonic currents and transient over currents and/or current ripples in DC systems.