Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkey
-
product
Air Core Current Limiting Reactors
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
product
Air Core Electric Arc Furnace Reactors
Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.
-
product
Air Core Harmonic Filter Reactors
Use of nonlinear loads such as power electronics based equipment and electric furnaces have been on the rise for the last decades. Such loads decrease the power quality of the network that they are connected to. One of the most important parameters for defining the power quality is harmonic distortion.
-
product
Air Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
Air Core Motor Starting Reactors
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
product
Air Core Neutral Grounding Reactors
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
product
Air Core Shunt Reactors
Shunt Reactors act as absorbers of reactive power to increase energy efficiency of the power system. Shunt Reactors are inductors that are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. The shunt reactors provide inductive compensation.
-
product
Air Core Smoothing Reactors
Smoothing Reactors are serially connected reactors inserted in DC systems to reduce harmonic currents and transient over currents and/or current ripples in DC systems.
-
product
Air Core Test Lab Reactors
Test Laboratory Reactors are designed for high voltage and high power test laboratories. They are designed to withstand the most extreme electrical service conditions during test periods. Design techniques are implemented in accordance with the most demanding service conditions. These reactors are used for various purposes in test laboratories such as current limiting and synthetic testing of circuit breakers, capacitor testing, artificial line simulation etc.
-
product
Anti-Condensation Heaters
Anti-Condensation Space Heaters are designed to maintain the temperature of an electrical enclosure. Anti-Condensation Heaters are used for elimination of water vapor contained inside the enclosures. They also provide frost protection by keeping the internal temperature of electrical enclosure above the freezing temperature. The Anti-Condensation Space (Panel) Heaters prevent condensation through convection.
-
product
Anti-Islanding Load Banks
AI-Series
AI-series anti-islanding load banks containing purely resistive, inductive, or capacitive load, have segmented combination control of power input, and can simulate a variety kinds of power loads to meet the grid-connected inverter full load test requirements.
-
product
Combined Load Banks
C-Series
C-series combined load banks are devices which contain resistive and reactive loads, apply the load to an electrical power source and dissipate the power of the electrical power.
-
product
Crowbar Resistors
Crowbar resistors are three phase resistance banks which are connected to the rotor windings of the DFIG (Doubly-Feed Induction Generator) such as wind power generator. They are used to prevent damage to the inverter circuits attached to rotor side when a fault occurs in the grid. DFIG power converter, which has a restricted over-current limit, needs special attention during faults in the grid. If the rotor current or DC link voltage reaches the threshold value, crowbar resistors disconnect the converter in order to prevent the generator turning into a squirrel cage induction machine. By crowbar resistors, the DFIG could stay connected to the grid and continue its operation.
-
product
Current Limiting Resistors
Current Limiting Resistors are designed for limiting the flow of current to some predetermined value and are used mainly to to keep flowing current within certain intervals while controlling the circuit.
-
product
dv/dt Filters