ALS Co., Ltd
ALS provides researchers with a wide range of products for electrochemistry and spectroelectrochemistry applications, including Bi-Potentiostat (Model 2325), Ring-Disk Electrode apparatus (RRDE-3A), Spectrometer Systems (SEC2000) and Faraday cage (CS-3A).
- sales@als-japan.com
Tokyo,
Japan
-
product
Ring Disk Electrode
This ring-disk type electrode developed by NTT Advanced Technology Corporation is a form of printed electrodes. Users can choose them from Carbon, Gold and Platinum applied versions. Available as a working electrode of radial flow cells, achieves complete reduction/oxidation on the center disk at ultra-low flow rate because of its fine coulometric electrolysis efficiency. This also enables to analyze subsequent reaction as well as identification and quantitation of the sample at the same time.
-
product
ITO (Indium Tin Oxide) Electrode
This quite unique material transmits only visible light whereas it does not transmit UV radiation. Our ITO electrodes consist of 100 nm thick of ITO layer deposited on quartz or borosilicate glass substrate (0.5 mm thick).
-
product
Flow Cell Kit
EQCMT
The two blocks of the EQCMT Flow cell are constructed using PEEK. It gives a high resistivity for chemical compounds.As well as QCM, these cell is reversible. With a inverted position of the blocks, it is possible to change from flow to static measurement.
-
product
Oxygen-free Voltammetry cell
SVC-3C
By using SVC-3C oxygen-free Voltametry cell, researchers can get rid of influence of oxygen in the cell by bubbling nitrogen gas, and also run the experiments at low temperatures.
-
product
Cell Stand
CS-3A
The CS-3A Cell Stand is adopted with CHI series Electrochemical Analyzers and other apparatus directly. The cell is enclosed in a Faraday cage to reduce electrical interference. A built-in gas control allows purging a sample. Gas line is provided to purge next sample, while analyzing the present sample separately, thus increasing productivity. Magnetic stirrer allows for controlling the mixing of the sample for experiments requiring mass transport of electrolyte or analyte to the electrode surface. Cell top positioner with detachable cell cap allows easy removal and replacement of the cell vial as well as the electrodes for rinsing, cleaning, and replacement.
-
product
IDA Electrodes
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
product
Bi-Potentiostat
2325
Model 2325 is a very low-price and high-performance Bi-Potentiostat based on modern semiconductor circuity and advanced software technology. Low noise, high speed and small space measurement were considerate for the development of Model 2325. The user-friendly interface is designed for supporting wide applications. Model 2325 can be applied in various experiments, such as RRDE, sensor development and spectroelectro-chemical measurements, etc. It can be not only applied for research purpose, but also for student experiments and industrial applications due to the low-price and high-performance.
-
product
Grid Electrode
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
product
Voltammetry Cell
SVC-2
SVC-2 Voltammetry cell can be used for 4 modes voltammetry cell setup. Each voltammetry cell has its specific feature. However, SVC-2 can be sed in 4 modes. Also can apply as an oxygen-free voltammetry cell.
-
product
Voltammetry Cell
VC-4
Capable for measuring of 1 - 3 ml of sample volume using electrodes with 6 mm of the diameter. Furnished holder prevents the vial from spilling.
-
product
Rotating Ring Disk Electrode
RRDE-3A
RRDE-3A is a constant rotation system for use in hydrodynamic modulation rotating ring disk electrochemistry. A 7 mm diameter electrode with short stainless steel shaft provides for a miniature and concentric circle electrode system that is capable for highly accurate rotation and modulation even at radial modulation rates or wave forms.
-
product
Flow Cell Kit
QCMT
The quartz crystal microbalance (QCM) technique under electrochemical frequency is very useful to determine many compounds such as metal proteins, metal ions and thiol-conjugated oligonucleotides.
-
product
Reference Electrodes
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
product
Spectroelectrochemical Cell
SEC-C
Spectroelectrochemistry (SEC) is aimed at the investigation of electrochemical reaction mechanism and the interface structure between electrolyte solution and electrode. Remarkable progress in this field and related technology enables SEC to be applied in wide areas.
-
product
Counter Electrodes
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.