Walk in Chamber for Altitude Simulated Test Relative Standard test requirements
Test Object: battery pack and system
Test Conditions: Altitude 4000m or the equate air pressure condition, atroom temperature.
The test objects stay in the test condition as Item 2 for 5 hours.
Subject the test object to 1C(no more than 400A) constant current discharge until reaching the cutoff condition.
After testing, observe for 2h under the room temperature.