Filter Results By:
Products
Applications
Manufacturers
RF Sources
Produce Radio Frequency (RF) signal.
- Pickering Interfaces Inc.
product
PXI/PXIe MEMS RF Multiplexer, Quad 4-Channel, 4GHz, 50Ω, SMB
40-878-241
The module is based on the latest micro-electromechanical system (MEMS) switching technology and has low insertion loss and VSWR. In addition, MEMS devices have a long operational life of >3 billion operations and benefit from an operating time of <20 μs allowing greater test system throughput. The multiplexers have excellent and repeatable RF characteristics beyond 4 GHz with each path having a nominally equal insertion loss.
-
product
Quad RF Driver
The Quad RF Driver contains four independent RF channels, each with an RF synthesizer, variable attenuator, and 1W power amplifier. The RF signal can originate from either the internal synthesizer or an external source via SMA input. All channels have independent frequency, phase, and gain settings and can be operated in one of two modes. The “Wideband” mode operates from 35MHz to 2GHz with a 3.472KHz resolution; over this range the frequency roll-off is approximately 0.5dB/100MHz. “Int-N Phase Adjust” mode allows the user to set and maintain a fixed phase relationship between all four channels. This mode is designed to operate between 300 and 460MHz with a 2MHz resolution. Two additional inputs are provided for an external frequency reference and digital modulation.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
SGMA RF Source
SGS100A
The R&S®SGS100A is an RF source designed to meet the requirements of automated test systems. It is available as a CW source or as a vector signal generator with an integrated I/Q modulator. With its frequency range of up to 12.75 GHz, the vector signal generation version covers the essential digital signals. The CW version can be used as a flexible local oscillator and for interference testing against mobile radio standards.
-
product
PCI Direct Digital Synthesizers
SYNTH300 SERIES
These devices provide two synchronized DDS-based RF channels on a single PCI card. With fine frequency and phase control, triggered operation, and the ability to accept an external clock, the Synth300 products enable a number of advanced applications at a fraction of the cost of conventional equipment. In addition to two analog outputs, the product can be ordered with one (or two) LVDS outputs for programmable digital clock applications, and can be configured for control by externally supplied TTL signals for low-latency triggered operation such as PSK, FSK, and triggered sweep operation.Software support for Windows Vista, Windows XP,Linux and Labview source code availableFor detailed specifications, please refer to the Synth300_Manual
-
product
4-in-1 OSLT Calibration Kit, DC to 40 GHz, 2.92 mm (m)
CK562A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM
HFDF
National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.
-
product
Ettus USRP X410, 1 MHz to 7.2 GHz, 400 MHz Bandwidth, GPS-Disciplined OCXO, USRP Software Defined Radio Device
787272-01
The Ettus USRP X410 integrates hardware and software to help you prototype high-performance wireless systems and perform over-the-air signal generation and analysis. Additionally, the Ettus USRP X410 features a two-stage superheterodyne architecture with four independent transmitter and receiver channels. It also features a Xilinx Zynq Ultrascale+ RFSoC with programmable FPGA supporting the Open Source UHD tool flow as well as LabVIEW FPGA. With these features, the Ettus USRP X410 has the RF and processing performance for applications such as wireless communications prototyping, spectrum monitoring, and signals intelligence. The Ettus USRP X410 is equipped with a GPS-disciplined 10 MHz oven-controlled crystal oscillator (OCXO) Reference Clock, which improves frequency accuracy and synchronization.
-
product
Digital RF Power &VSWR Measurement System
PowerMaster II
Thank you for purchasing the Array Solutions PowerMaster II RFPower/VSWR Indicator. The PowerMaster II represents a breakthrough in features for measurement of the performance of your transmitting system. Microprocessor control insures fast capture time and low power consumption. With the ability to monitor your VSWR and power levels at all times, you will know that your transmitter, RF source, and load, or antenna systems are operating effectively and safely. In addition, the power and VSWR relay alarms can quickly shut down your power amplifier system and alert you to the alarm condition. This places an additional layer of protection in your transmitting system to help preserve expensive tubes and finals. The PowerMaster II also features the ability to be monitored and controlled from a PC using the software downloadable from our website, and the unique ability to be monitored and controlled over a LAN or from the internet. PowerMaster II firmware updates will be posted for download from the Array Solutions website as they become available. This means that the user can take full advantageof features or enhancements just by installing the firmware update. No need to return the meter to the factory for updates
-
product
1-Channel DAQ Module
FMC160
Sundance Multiprocessor Technology Ltd.
The FMC160 provides one 12-bit A/D channel at 3.6Gsps and one 14-bit D/A channel at 5.6Gsps (2.8Gsps direct RF synthesis) clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users. The FMC160 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).
-
product
Zero Bias Schottky Detectors
Fairview Microwave’s line of coaxial packaged zero bias Schottky detectors feature matched inputs for excellent VSWR, voltage sensitivity levels that range from 100 to 500 mV/mW for small signal detection, negative video output polarity, and can withstand maximum input power levels up to +20 dBm CW. Operating temperature range covers 0°C to +90°C and storage temperature of -65°C to +125°C. These zero bias Schottky detectors utilize compact cylindrical package outlines that are made of passivated stainless steel and offer a variety of popular input/output SMA and BNC connector configurations that make them ideal for use with precision test and measurement, instrumentation, and subsystems assemblies. Numerous applications include power measurement, leveling pulsed signal sources, AM noise measurements, radar or missile guidance systems, monitoring system level performance, and pulsed RF measurements.
-
product
Laser Power Meters
Laser Power meters are a vital tool in your Preventative Maintenance regime.They allow you to quickly test the the performance of your optical system (laser source / mirrors / lens) and pin point any potential issues before they can affect your product quality and production throughput.Power meters are great for determining if specific components are starting to deteriorate, allowing you to order and replace without impacting too seriously on your production.The power meter measures the laser output for the following laser sources and wavelengths:CO2 Glass DC Laser Tube / 8~11 microns or 8,000 ~ 11,000 nm wavelengthCO2 RF Metal or Ceramic Laser / 8~11 microns or 8,000 ~ 11,000 nm wavelengthYAG Laser / 900 ~ 1250nm wavelengthFiber Laser / 900 ~ 1250nm wavelength
-
product
RF Synthesizers Modules
Holzworth Instrumentation, Inc.
Holzworth's RF Synthesizers Modules were originally designed as the internal, tunable LO test sources for Holzworth phase noise analyzer products. Due to the need for easy integration, the HSM Series designs incorporate a long list of electrical and mechanical features to satisfy the demanding requirements of today's high performance communications systems and integrated test systems. FIELD PROVEN RELIABLITY with MTBFs exceeding 240kHrs.
-
product
RF Reference Source
96040A Series
The 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system.
-
product
Filtered DC Interface Module
DC modules for RF Test Enclosures eliminate conducted and radiated interference, while providing a source of DC power.
-
product
Gigavac Power Contactors, Switches & Fuses
All high power relays, power contactors, and DC disconnect switches are designed and manufactured at our state of the art factory in Carpinteria, California. GIGAVAC’s extensive line also includes compact high voltage relays and high voltage reed relays for specialized DC and RF application requirements. With an engineering staff of thirty plus we can also provide special modifications to meet your every need. Looking for a relay distributor or contactor distributor? GIGAVAC invests in having inventory to provide most products from stock or within a short lead-time. You can purchase high voltage relays, DC contactors, manual disconnect switches, or other GIGAVAC products from one piece to thousands directly from GIGAVAC, your source for Advanced Switching Solutions.
-
product
Test tools
Try our low-cost RF sniffers for fast and easy troubleshooting of unwanted interference caused by electromagnetic radiation sources in your local environment.
-
product
PXI-2549, 2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module
778572-49
2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module - The PXI‑2549 is a general-purpose single‑pole double‑throw (SPDT) switch module. You can use it to add flexibility to your switch network or to maintain uniform signal paths across multiple channels when building high‑channel‑count multiplexers. The PXI‑2549 termination resistors minimize reflections on open channels and protect your source or device under test from damage. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
Noise Location Package
Type HFDF
National RF’s Type HFDF high frequency location system is a proven noise hunting and location directional antenna system that allows you, in many cases, to walk right up to the source of High Frequency (HF) noise! Used by several power companies around the United States, professional noise hunters, and other communications specialists, the HFDF has located noise sources that emanated from pole power transformers, arcing electric fences, CATV in-line amplifiers, plasma TV screens, and even Marijuana grower’s heating lamps! The system incorporates several plug-in, tunable magnetic loop sensors of a proprietary National RF design, that cover the frequency range between 1.8 MHz and 55 MHz. The unit is packaged in a hand-held, lightweight metallic enclosure, with a pistol grip and a magnetic compass mounted on top. The compass is used to get magnetic bearings to the noise source, which may be plotted on a map to triangulate, and ultimately pin-point, the location of the noise source. In certain cases, our customers tell us that they have been able to walk right up to the interfering noise source and correct the situation on the spot!
-
product
RF / MW switch
The RF / MW switch includes a variety of RF and microwave switch modules - RF multiplexers, which are available for use in the 34980A multifunction switch / measurement unit, providing broadband switching from DC to 20GHz . Use these modules to route test signals between your device under test and a signal source, oscilloscope, spectrum analyzer, or other instrument. The switch / attenuator driver module also controls the external switches and attenuators of the 34980A.
-
product
Handheld Broadband Noise Generator
NS-1
The Model NS-1 is a handheld broadband white Gaussian noise source. It generates a wide, even, RF noise-signal. The NS-1 is popular for testing network components and aligning a building's coaxial cable network. The NS-1's noise-signal is also used to provide the RF source for measuring insertion loss of cable, splitters, taps and more.
-
product
PXI RF Relay Module
PXI RF Relay Modules offer single-pole double-throw (SPDT) and terminated switches. SPDT models include excellent insertion loss, voltage standing-wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay-count-tracking feature on these models to predict relay lifetime and reduce unexpected system downtime. SPDT models are also well-suited for passing high-order harmonics from PXI RF Signal Upconverter Modules or routing multiple sources to PXI RF Signal Downconverter Modules. Terminated switch models feature front-mounted SMA connectors and high-performance solid-state relays for fast switching time and unlimited mechanical lifetime. These models also include termination on every COM line and channel, which helps minimize reflections of the RF signal and protect your instruments.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF6 set
The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Low Phase Noise Reference Source
96270A
The 96270A RF Reference Source is the simplest, most accurate and cost-effective single instrument for calibrating spectrum analyzers and RF power sensors and more, up to 27 GHz.
-
product
Low Noise Pre-Amplifiers
Low Noise Pre-Amplifier and companion external low noise amplifier (LNA) are used to amplify low level microwave signals. The Pre-Amplifier contains an AC/DC power supply, internal low noise amplifier, and a bias tee to source a DC bias voltage on the RF input connector.To overcome cable loss between the test antenna and the Pre-Amplifier assembly, a remote low noise amplifier (LNA) is mounted directly onto the 10 GHz antenna. A bias tee inside the Pre-Amplifier chassis powers the remote LNA through the coax cable interconnecting the pre-amplifier and the 10 GHz test antenna.
-
product
SSA-X Signal Source Analyzer, 1 MHz To 8 GHz
E5055A
The Keysight E5055A SSA-X signal source analyzer provides precise and accurate measurements in one box. Comprehensive and versatile, this solution evaluates the phase noise and other relevant parameters for RF signals up to 8 GHz. Flexible measurement settings and a modern user interface improve measurement efficiency, while application support through software expands measurement coverage to meet new requirements.
-
product
RF Noise Source
NS-3
The NS-3 Broadband RF Noise Generator provides an extremely flat AWGN (Additive White Gaussian Noise) signal from 5 to 2150 MHz. The output level adjusts in 0.1 dB steps over a 30 dB range.The bench-top configuration is standard and an optional two unit rack enclosure is available. The RS232 or USB remote control interface simplifies its use in automated test and factory ATE environments. The NS-3's combination of range, versatility and value make it the ideal general purpose broad-spectrum signal source for bench and ATE applications, including C/N, BER, MER, PER testing and rain fade simulation.
-
product
FPGA Mezzanine Card
FMC165
The FMC165 provides two 14-bit analog-to-digital (A/D) channels supporting RF sampling at 2.6 GSPS and one 14-bit digital-to-analog (D/A) channel with sampling rates up to 5.2 GSPS (2.6 GSPS direct RF synthesis). The converters are clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users.
-
product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
PXI-2599, 26.5 GHz, 50 Ω, Dual SPDT PXI RF Relay Module
778572-99
26.5 GHz, 50 Ω, Dual SPDT PXI RF Relay Module - The PXI‑2599 is a general-purpose single‑pole double‑throw (SPDT) switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2599 is also well-suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
PXI-2598, 26.5 GHz, 50 Ω, Dual-Transfer PXI Transfer Switch Module
778572-98
26.5 GHz, 50 Ω, Dual-Transfer PXI Transfer Switch Module—The PXI‑2598 is a general-purpose switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2598 is also well suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking to predict relay lifetime and reduce unexpected system downtime.