Filter Results By:
Products
Applications
Manufacturers
Electro-Chemical
chemical action when combined with electricity.
- PalmSens BV
product
Potentiostat / Galvanostat / Impedance Analyzer
PalmSens4
PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS). The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. This instrument is a complete laboratory instrument but its compact and rugged design makes it also ideal for field work.
-
product
Potentiostat/Galvinostat Electrochemical Instuments
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
product
Electrochemical Workstations
Besides a potentiostat / galvanostat all our electrochemical workstations include also a frequency response analyzer unit (FRA) in their basic configuration. This makes each of our electrochemical workstations a highly versatile basis equipment for a multitude of electrochemical investigation methods on batteries, accumulators and fuel cells as well as on high impedance objects such as coatings and laminates. Due to their hardware extensions slots our instruments can be extended to multi purpose data acquisition and control test stands.
-
product
Electronic Loads
AMETEK Programmable Power, Inc.
Electronic loads have found a variety of applications ranging from power converter testing to current modulation. A large range of power sources can be tested using an electronic load from converters, inverters and UPSs to electrochemical sources such as batteries and fuel cells.
-
product
CellTest Multichannel Potentiostat
Simultaneous Electrochemical Impedance Spectroscopy (EIS) tests can be run on multiple cells by connecting Solartron 1455A/1451A series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455A FRA provides high performance impedance measurements over the frequency range 10 μHz to 1 MHz, while the 1451A FRA operates from 10 μHz to 100 kHz.
-
product
Tribocorrosion Tester
ASTM G119
Tribocorrosion involves studying Wear Evaluation of Protective Coatings. It involves mechanical and electrochemical interactions between components in motion. Rtec Tribocorrosion modules measures inline current, voltage, friction, wear, temperature , down force, ear, acoustic emissions at all times. Currently used by several Fortune 500 firms globally.
-
product
Carbon Monoxide Detector, CO
ENVIROMUX-CMD
Continuous air monitoring. Pre-set alarm points alert at: 70 ppm after 60 to 240 minutes; 150 ppm after 10 to 50 minutes; and 400 ppm after 4 to 15 minutes. Flush or surface mount. Test functionality of electrochemical CO sensing cell. Connect to RJ45 or digital input sensor ports. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1000 ft (305m). LED indicators for operation status and system test. Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL.
-
product
Low Power Wireless Gas Detector
CX
Teledyne Gas & Flame Detection
Model CX sensors are equipped with standard analog 4-20mA, and Modbus™ RTU RS-485 outputs and can be used with SmartWireless Site Sentinel CX/CXT controllers. The CX is a very low power device making it an ideal choice for a battery powered detector (optional) in applications where power is unavailable or not economically feasible.CX gas detection sensors are easily and economically deployable in both permanent and temporary installations. These low power sensor assemblies utilize electrochemical technology for a long list of toxic gases.
-
product
IDA Electrodes
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
product
Chloride Test System
C-CL-2000
The C-CL-2000 produces results on-site, within minutes that are accurate and comparable to expensive laboratory tests. It measures the electrochemical reaction of a weighted sample placed in an extraction liquid. It automatically shows a temperature compensated reading of percent of chlorides on its digital display. A wide range - from 0.002 to 2% chloride by weight - is covered.
-
product
Carbon Monoxide Detectors
Inspector CO Detectors
Sensorcon, Sensing Solutions by Molex believes in the importance of a dependable gas detector. Featuring proprietary engineering & software, our Inspector Series utilizes electrochemical sensors for fast & accurate measurements of CO.
-
product
Formaldehyde Analyzer
KT-2010
Sensor type: electrochemical type·Resolution: 1ppb·Measuring range:4.0ppm/40ppm·Degree of accuracy: ±3% ·Response time: ≤50 seconds ·Working temperature: 0 to 45℃·Computer interface: RS232·Power supply: 1.5V x 2AA
-
product
Trace Oxygen Analyzers
Alpha Omega Instruments trace oxygen analyzers and transmitters incorporate an advanced electrochemical sensor that provides exceptional life, accuracy, and stability. Alpha Omega Instruments electrochemical sensors provide as much as three times the life of conventional “fuel cell” type sensors. And, if you are looking to measure from parts per billion to 100%, Alpha Omega Instruments offers a high-performance zirconium oxide oxygen sensor.
-
product
Signal Generators
"Signal generator" is the generic name for instruments which produce time - dependent voltages which are used to stimulate other processes, e.g. electrochemical reactions. Standard types are ramp generators, also called sweep generators which produce linearly varying voltages, pulsgenerators, sine wave generators and arbitrary signal generators. Generally, D/A - converters are also to be regarded as "signal generators". This page, however, deals with stand-alone signal generators only.
-
product
Electrochemical Sensors
Electrochemical sensors are devices that provide real-time information about the composition of a system by connecting a chemically selective layer (recognition element) to an electrochemical transducer
-
product
Cells and Electrodes
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
product
Hazardous Area Gas Detector
Meridian
Teledyne Gas & Flame Detection
Whether you need an infrared or catalytic bead sensor to detect combustible gases or an electrochemical sensor for a toxic environment, the Meridian universal gas detector utilizes a single detector head to easily accept all sensor types. There is no requirement for distinct personality boards in the gas detector or different detector heads to make the instrument behave as a combustible or toxic gas detector. The Meridian gas detector accepts all sensor types in one detector. Simply attach the specific toxic or combustible sensor to the universal detector head and the Meridian gas detector will automatically determine the type of gas to be detected. Installation of the sensor is a simple plug-and-play action. At Teledyne Gas and Flame Detection, we are always looking to anticipate your future needs. We designed the Meridian gas detection platform to be future proof, allowing you to take advantage of new sensing technologies from Teledyne Gas and Flame Detection while maintaining ease of use and peace of mind.
-
product
The Golden STM
*Golden (chemically resistive) vibration isolated STM body with implemented preamplifier*Computer with PCI board based SPM controller *Anfatec Scan & Anfatec Present*19“ STM controller (extra low noise 24 bit converters)*HV display for z-direction*High voltage amplifiers for the x-y-tube scanning*Optional: PC controlled bi-potentiostat and electrochemical cell
-
product
Process Percent Oxygen Analyzer
GNL-IN962
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-IN962 oxygen analyzer is an intelligent oxygen analyzer that is based on microprocessor, keeping gas electrochemical sensor as measuring unit with high intelligence, accuracy and long service life. It has been used in oxygen concentration in many industries under various environments. - See more at: http://en.ci-ele.com/79b7fcd3-aee7-30a4-9cf8-76748ef33dcc/16c2beac-ce45-7aaa-50ed-8b48397f3a15.shtml#sthash.1UMwSmEm.dpuf
-
product
Dynamic UPS
ROTOBLOC® RBT SERIES 400 - 2000 kVA
The RBT system consists of a standard synchronous generator with no special windings and a simple steel flywheel. The low speed shaft extends bearing life and reduces maintenance. The ROTABLOC® machine is very robust as critical functions do not use fragile components such as power electronics, power capacitors, electro-chemical batteries, active magnetic bearings, electro-mechanical or mechanical friction clutches.
-
product
Radiometer Analytical Probes
Radiometer Analytical develops and manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes and conductivity cells - for every application and budget.
-
product
Time-Resolved Electrochemical Quartz Crystal Microbalance
400C Series
The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).
-
product
Bipotentiostat
700E
The Model 700D series are computerized general purpose potentiostat / bipotentiostat / galvanostat instruments. A typical application involves a rotating ring-disk electrode (RRDE), but these systems can also be used for other applications where dual channel measurements are essential, such as dual channel electrochemical detection.
-
product
Oxygen Analyzers for Process, Industrial & Fail-Safe Applications
The O2 analyzers from PST offer oxygen sensor technologies such as zirconium dioxide, thermo-paramagnetic and electrochemical. These highly reliable oxygen analyzers provide various installation options such as bench, panel, rack and wall mounting.
-
product
Electrochemistry
Modular Line
The Modular Line of instruments consists of a range of instruments to suit any requirements in electrochemical research, from low to high voltage and from low to high current.
-
product
Potentiostat Galvanostat
1287A
The Solartron Analytical 1287A potentiostat and galvanostat is a high accuracy, wide bandwidth instrument which offers a range of DC test capabilities. The 1287A can be coupled with a frequency response analyzer, such as the Solartron Analytical 1260A or 1255B, and ZPLOT software for AC tests such as Electrochemical Impedance Spectroscopy.
-
product
Pine Research Instrumentation
Known as a forefather in the development and production of electrochemical research equipment, Pine continues to support research and development activities worldwide through a family of vertically integrated resources represented by Pine Research Instrumentation. With a comprehensive team of engineering production, sales and support professionals Pine Research is well positioned to meet the industry's needs from its location in Durham, North Carolina.
-
product
Trace Moisture Analyzer
PPM1
Model PPM1 is a trace moisture analyzer designed specifically for monitoring moisture levels in dew point and PPM units. This trace moisture analyzer utilizes an electro-chemical (P205) sensor in combination with a proprietary semi permeable diffusion membrane.
-
product
Electrochemical Analyzer
EC Epsilon EClipse
The Epsilon EClipse™ is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. It comes with software that enables the most popular electrochemical techniques such as cyclic voltammetry, chronoamperometry, and chronopotentiometry (select Techniques below for a more complete list). The Basic Plus software can be purchased to enable pulsed voltammetry and stripping voltammetry techniques.
-
product
Coupled Multielectrode Array Sensor (CMAS) Probes
CMAS probes are made from user-specified sensing materials, including carbon steels, stainless steels, and nickel-, aluminum-, and copper-based alloys. They can also be made from customer supplied materials that have the same microstructure/heat treatment as the system component materials to be monitored. The size of the sensing electrode varies from 0.1 to 3 mm (0.004" to 0.12") in diameter, depending on the application. Typical numbers of electrodes in a CMAS probe are 9, 16 or 25 for online corrosion monitoring and vary from 8 to 100 for laboratory corrosion and electrochemical studies.