Filter Results By:
Products
Applications
Manufacturers
Total Harmonic Distortion
Is a measure of a signal's sum power of all harmonic components to the power of the fundamental frequency.
See Also: Distortion, Intermodulation Distortion, THD
-
product
Ultra-Low Distortion Function Generator
DS360
Stanford Research Systems, Inc.
The performance of a low distortion analog source and the precision of direct digital synthesis (DDS) is combined in the DS360. With less than 0.001 % total harmonic distortion (THD), 25 ppm frequency accuracy, and a broad range of features including sweeps and bursts, the DS360 is the ideal source for audio frequency applications.
-
product
Digital Power Meter (Harmonic Analyzer Model)
LS2010
• Measure Vrms, lrms, W, PF, Hz; • Harmonic distortion analysis for voltage & current, display total harmonic and 0-50 times; • Component harmonic, selectable for absolutely or relatively harmonic display; • Voltage range: 10.0-600.0V, Current range: 0.010-20.00A, Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit); • Simultaneously display Vrms, lrms, W, PF value on 4 windows, suitable for production line; • Can test every kinds of curve; Print both data & curve; • Communication port for PC, run under WinXP or Win7.
-
product
40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger
SD750100G
Zhejiang Sandi Electric Co., Ltd
40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.FeaturesProduct Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interface (Optional)SpecificationModel SD750100GAC input Input system Three phases + PEVoltage range 280Vac ~500VacRated voltage 440VacFrequency range 50Hz/60HzMaximum current <74AITHD (total harmonic distortion) <5%DC output Output power 40KWVoltage range 50-750Vdc ( can set)Constant power output voltage range 400Vdc-750VdcOutput current range (A) 100A ( 1~100A can set)Output current limit 1-100A continuously adjustableSteady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%
-
product
AC / DC Digital Power Analyzer
4016(800Vp,20Arms/200Ap)
To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.
-
product
AC-DC Power Supply Solutions
Advanced Conversion Technology, Inc
From single to three phase inputs, 60 Hz or 400 Hz, ACT can provide you with a design to meet your demanding applications. ACT can also provide designs that incorporate an active PFC front end, single and three phase, which provides less than 3% total current harmonic distortion.
-
product
AC Power Source
LSP-500VAR
• AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU • Protection for over hot, thundering voltage and current • Total voltage distortion: ≤0.3%; Voltage stability: ≤0.05%/30min • Load adjust rate: ≤0.05%; Frequency stability: ≤0.01%/30min • Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz • It is pure sine wave AC power source with low harmonic and high accuracy • Input Power: 220V and 50/60Hz (110V can be option) • Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.
-
product
AC Power Source, Frequency Converter
BL1350 Series
Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less than 0.5%, high efficiency, plus excellent line and load regulation.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Clamp-on Meter
SDC96
True RMS for AC measurement. Total harmonic distortion [50Hz/60Hz] for AC. Measurement. Peak measurements. Measures up to 700 AC/DC amps
-
product
Digital Power Meter (High Accuracy Model)
LS2050
LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.
-
product
G.fast Transformers
Our line of G.fast transformers are the preferred choice of engineers seeking the most reliable, functional isolation transformers for G.fast transmission. These compact transformers deliver excellent longitudinal balance and total harmonic distortion performance.
-
product
LCD Power Meters
Accuracy ±0.1% F.S. Measuring and display ACV/ACA/Watt/Var/VA/Power Factor/Frequency/KWH/DM(Demand) Input measurement network can be selectives(1P2W/1P3W/3P3W/3P4W) CT rate/PT rate can be modified(1 to 9999) Measuring ACV/ACA total harmonic distortion(THD),up to 35th harmonic(optional) Two alarm control function (optional) Two pulse output function (optional) Digit RS-485 interface function (Optional)
-
product
mAEStro Audio Analog to Digital Converter
The mAEStro AADC-100 accepts balanced stereo analog audio inputs and converts them into a single digital bit stream in compliance with the AES/EBU (AES3) and S/PDIF digital audio standards. It generates 24-bit values and uses 128 times over-sampling for extremely accurate and linear analog to digital conversion, as well as offering a high dynamic range with exceptionally low total harmonic distortion and noise.
-
product
Operational Amplifiers
Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.
-
product
Power Analyzers & Wattmeters
Measurements International Ltd.
Direct Replacement for 2010A Wattmeter in the AccuLoss® Loss Measurement Systems, Basic Power Accuracy < 0.005 %, 10 Current Ranges, 2 Voltage Ranges, Line-and-Line and Line-to-Ground Voltage Measurements, Full Power Factor Range, Complete Waveform Analysis, Total Harmonic Distortion Analysis, Phasor Analytical Representation.
-
product
Power Quality Analyzer
Power quality analyzer is a product carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, man-machine operation and concise and comprehensive test instrument. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
-
product
Power Quality Meter
Qualstik
The Qualstik Power Quality Meter has been developed specifically for measurement of four important items of power quality in the electric utility industry. These are Current, True Power Factor, Total Harmonic Distortion and the Direction of Current Flow.
-
product
Distortion Analyzer
SINAD
SINAD utilizes the latest in Digital Signal Processing (DSP) technology to accurately measure several key performance characteristics of radio receivers by analyzing the spectral content of a received audio signal.
-
product
Distortion Detector
DD-1
The purpose of this tool is to enable the installer to set the gain of an audio amplifier to match the source unit's output level, accurately and quickly. It can also be useful for detecting distortion in the audio signal caused by poorly designed or malfunctioning audio equipment.
-
product
Harmonic Filters
ENTES Harmonic Filter Reactors are used in serial connection with capacitor banks in power factor correction units. By using these types of detuned reactors it is possible to increase the capacitor impedance against harmonic currents and to keep the resonance frequency under the frequencies in which main harmonic currents occur by shifting the resonance frequency.
-
product
Harmonic Mixers
These waveguide bandwidth harmonic mixers are designed for use with spectrum analzyers with diplexers, such as the Tektronix 492 and 494 and the Hewlett-Packard 8555A, 8565A and 8569A. They are also used as phase locking and receiver mixers for antenna measurement systems such as the Scientific Atlanta wide range receivers. When used with an external diplexer*, these harmonicmixers can be used to phase lock millimeter wave sources.
-
product
Harmonic Generators
Our harmonic Generators include Doubler, Tripler, and Quadrupler for doubling, tripling, and quadrupling laser frequency in the wavelength range 680-1300nm. The second harmonic, third harmonic, and fourth harmonic generation up-convert the laser frequency to a wavelength range 190-650nm. These harmonic generators greatly expanded the application of wavelength range for femtosecond and picosecond lasers available for both amplifiers and oscillators.
-
product
Total Solution
SD 4.1 Family
To meet the ever increasing data transfer rate in high end applications, such as professional broadcasting transmission or advanced high resolution display, the SD 4.1 specification calls out the maximum performance of 1.56 Gbps at UHS-II full duplex mode per lane or half duplex UHS-II at 3.16 Gbps. In real applications, due to the system overhead and different SD 4.1 device controller designs, the actual measured performance can vary dramatically from system to system. With the newly introduced ADMA 3, the OS driver is now able to issue multiple read or multiple write commands at once, without having to wait for the SD controller to complete one command at a time. Once the SD host controller has collected multiple commands, it will then manage and complete them without intervention from the host software drive. Thus, the UHS-II 1.56 Gbps interface can be more effectively utilized and maximize the system throughput. This feature can be very useful when running multithreaded applications where multiple applications are constantly updating their status or swapping their contents by writing or reading small chunk of data to or from the memory card.
-
product
Total Stations
Zoom50 Series
When you need highest performance on all levels even under most challenging conditions, the GeoMax Zoom50 series is the perfect choice for you. The longer measurement range means a wider operational coverage and significant less time lost with switching setups. The new PowerLock protection mechanism prevents use by unauthorized persons and deters theft.
-
product
Total Stations
Zoom40 Series
The Zoom40 manual total station, with its high resolution color and touch display, gives you the flexibility to run X-PAD, Field Genius, SurvCE, or any custom windows CE software.
-
product
Total Stations
GeoMax total stations offer you an excellent price-to-performance ratio without compromising quality.
-
product
Total Stations
X-Pole
Work simultaneously with Total Stations and GNSS by combining the advantages of both systems. GeoMax X-POLE significantly improves the performance and flexibility on the jobsite.