Integrating Spheres
Uniformly scatter or diffuse light rays.
See Also: Goniophotometers, Spectroradiometers
-
product
Precision Kelvin Holders
MH-4 Series
Integrating Spheres are essential tools for photometricresearch laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary.
-
product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
-
product
Calibration Light Source
CAL1
Image Engineering GmbH & Co. KG
The one light source solution in the field of camera characterization and calibration. CAL1The CAL1 calibration light source is designed to characterize and calibrate cameras in the lab or on the production line. Its compact design consists of one iQ-LED element in a 0.3 m integrating sphere that illuminates a 70 mm opening. Because of the non-reflective special diffusor filter on the sphere opening, a uniformity of more than 98% could be reached
-
product
Total Flux Measurement Systems
LED’s and Luminaires must be characterized and tested for brightness and color, for production quality control and also for R&D. The Gamma Scientific Total Flux Measurement System combines our accurate Radoma Spectrometer and an integrating sphere for total flux (total power) and color measurements of LED, micro LED and Luminaires. Measurement parameters include spectrum, lumens, total power, peak and dominant wavelength, CRI, CCT, FWHM and other optical properties.
-
product
Constant Temperature Integrating Sphere
IS-*MT
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Integrating Sphere FT-NIR Spectrometer
QuasIR 3000™
The QuasIR™ 3000 was designed from the ground up to offer the industry a new kind of NIR analysis solution – a solution that brings together the portability required to move NIR analysis closer to point-of-need, combined with unmatched spectroscopic performance for the fastest and most accurate results.
-
product
Spectrophotometer & Integrating Sphere Test System
LPCE-1
This Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry.
-
product
Integrating Sphere Solutions
An integrating sphere is a light collector which takes advantage of physical geometry to homogenize any radiation being emitted inside by relying on a high-reflectance coating material. Depending on the wavelength range the end user using a sphere with, different coatings have different advantages based on the application.
-
product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
UV-VIS-NIR Spectrophotometer
UV-2600i, UV-2700i
The compact UV-2600i/2700i is a universal, research-grade spectrophotometer that can be used in a wide range of fields, and easily expanded to suit the measurement objective. By using the optional integrating sphere, the measurement wavelength range of the UV-2600 can be extended to the near-infrared region of 1400 nm. The UV-2700 is capable of 8-Abs measurements, and optimal for measuring low transmittance samples.
-
product
Integrating Sphere With Holder Base
IS-*MA
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as T5/T8/T12, and all kinds of luminaries2. The hold base can be installed in the ceiling or down, it can be adjusted the height3. Hold base has four power cables connect to the outside Power Supply and max is 5KW4. The holder base is detachable. For some kinds of light sources you may need to change the position of the holder base.5. Diameter: IS-0.3M (0.3m), IS-0.5M (0.5m), IS-1.0MA (1.0m), IS-1.5MA (1.5m), IS-1.75MA (1.75m), IS-2.0MA (2.0m). Other sizes can be designed according to the customer’s request.6. The painting of integrating spheres is according to CIE Pub. No.84 (1989)
-
product
High Precision Spectroradiometer Integrating Sphere System
LPCE-2(LMS-9000)
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
-
product
LED Tester0.3m-2m Integrating Sphere
CX-8000
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Integrating Spheres For UV
Konica Minolta Sensing Americas, Inc
Instrument Systems offers complete measurement solutions for UV-A, -B and -C radiation starting from 200 nm. The operation of the well-proven Instrument Systems spectroradiometers, e.g. CAS series, with integrating spheres made from PTFE facilitate high sensitivity measurements of UV radiant flux.
-
product
Target Wheels
Santa Barbara Infrared manufactures a wide variety of standard and custom target wheels, to conveniently and accurately position multiple targets in front of a blackbody source. The SBIR 300 Series Target Wheels are specifically designed to be used with SBIR’s standard differential blackbody sources and integrating sphere light sources. These motorized target wheels are available in several standard models to accommodate different sizes and numbers of targets.
-
product
UV Penetration & Protection Test System
TF131
TESTEX Testing Equipment Systems Ltd.
UV Penetration & Protection Test System. Fabric Samples are measured in a double beam spectrophotometer with an integrated sphere. The sample is scanned over the UVA and UVB regions of the spectrum and transmitted radiation is efficiently collected by the detector within the integrating sphere. The software calculates UV penetration factors and sun protection factors from the scan data. It runs on a PC under Microsoft Windows and controls the spectrophotometer, automates the measurement process and generates a printed report. PC and printer are not included.
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of inte...show more -
product
Optical Path Converter
LS512A/LS512B
There are many LED manufactories using two integrating spheres and one spectrophotometer to do test. The previous testing way is: when you use big sphere to test, the customer need to connect the detector cable and optical fiber from the Spectrophotometer to the big sphere, after the calibrating and then you can do the test. When you use the small sphere, you need to take away the detector cable and optical fiber from the big sphere to the small sphere, then need to calibrate again. It is t...show more -
product
HAAS-3000/2000 High Accuracy Array Spectroradiometer (Laboratory Grade)
HAAS-3000
Hangzhou Everfine Photo-E-Info Co., LTD
HAAS-3000/2000 High Accuracy Array Spectroradiometer delivers various photometric, colorimetric and radiometric parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
product
*High Speed, Multifunctional Integrating Spheres
Multifunctional integrating spheres enable simultaneous measurement of multiple laser parameters including:*Power*Pulse Characteristics*Spectrum
-
product
High Power Optical Head With Integrating Sphere
81628C
The 81628C High-Power Optical Head features an integrated sphere that enables it to handle power levels up to +40 dBm (with heat sink), across 800 nm to 1700 nm wavelength range. It provides the highest accuracy at high power within the family.
-
product
Integrating Spheres
Integrating spheres are used especially for measuring divergent light sources such as LEDs. The light is introduced through the input port, then reflected many times by the highly reflective interior of the sphere until it illuminates the inner surface uniformly. A detector samples a small fraction of this light to measure the total power input. Ophir integrating spheres have a highly reflective diffuse white coating for measurements independent of beam size, position and divergence. There are several sphere sizes, apertures and wavelength regions available. The large IS6 series has 2 configurations for measuring divergent or parallel beams.
-
product
Photometric Testing Services
LLI. offers a wide variety of services to fulfill your photometric, color and electrical testing needs. Using our custom, rotating mirror, Type-C goniophotometer, in combination with various integrating spheres, we are able to test many different types of lighting fixtures and light sources. LM-79 -08 Test & LM-80 Test, SSL Photometry Testing, Energy Star®, CEC Title 24, DesignLights Consortium® (DLC), Custom Tests and UL / ETL Safety Test Consultation.
-
product
UV-Vis & UV-Vis-NIR Systems
Our range of powerful and productive UV-Vis and UV-Vis-NIR molecular spectroscopy systems offers options for any optical application. The Cary 60 Spectrophotometer has a unique Xenon flash lamp to enable remote sampling, while the Cary 4000 allows you to measure highly turbid solutions without an integrating sphere. The Cary 8454 photodiode array captures the complete UV-Vis spectrum (190-1100nm) in less than one second.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
Light Analysis
Welcome to Thorlabs; below you will find links to detectors and instrumentation that measure the various properties of light, a subset of our entire line of photonics products. Thorlabs offers an extensive selection of instruments that measure the properties of light. Our versatile power and energy meters can be used with over 25 different sensors in order to make NIST-traceable power and energy measurements. If the convenience of a meter is not desired, our selection of detectors includes basic...show more -
product
PCE Series Opto-Electric Measurement System
Hangzhou Everfine Photo-E-Info Co., LTD
This system delivers various photometric, colorimetric and electrical parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
product
Reflectance/Transmittance Test Set
RT-500
An Integrating Sphere is a hollow sphere which has its interior coated with a paint that is nearly perfectly diffuse or Lambertian and which has extremely high reflectance. Light energy introduced in an integrating sphere is reflected from the wall and distributed uniformly around the interior. A detector which is placed at a hole or 'Port' in the sphere wall sees an output which is completely independent of the angularproperties of the input light. The independence of the output of a sphere from the angular properties of the input and the uniform internal distribution of light make integrating spheres ideal for many uses.
-
product
CAS-200 Compact Array Spectrometer
CAS-200
Hangzhou Everfine Photo-E-Info Co., LTD
CAS-200 can quickly and accurately measure the spectral power distribution in the range of 380nm ~ 780nm, mainly measuring: the relative spectral power distribution, chromaticity coordinate, color temperature, color rendering index, color tolerance, peak wavelength, FWHM, luminous flux (with integrating sphere) of traditional lamps/light sources, single LED, LED modules and other electric light sources.
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ)...show more