Filter Results By:
Products
Applications
Manufacturers
3 Phase
three voltage waveforms at 120°,1/3 of a cycle offset in time.
See Also: Phase Rotation, Phase
- Pickering Interfaces Inc.
product
PXI 4-slot BRIC Matrix, 126x12, 1 pole (3 Sub-cards)
40-558-401-126x12
The 40-558-401-126x12 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
Phase Sequence Indicator
PHS 863
Two Functions in one unit including open phase and phase sequence. Large Size alligator clips can easily clip on switch-board terminal. Highly Reliable : Identifies 3 phase sequence and open phase check. Functional design : This model is ideal for installing conveyor lines, pump systems and interconnected drivers. Safety approval : CE marks EN 6101-1 CAT. III. EN 61010-2-031
-
product
LV Iron Core Motor Starting Reactors
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
product
Regenerative AC Emulator, 600 VAC, 63 A, 30 KVA, 3‑Phase
SL1201A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
LED Synchroscope
LS-96 SYNC
Standard Electric Works Co., Ltd
● Input Voltage : 110V AC, 120V AC, 220V AC, 230V AC or 240V AC.● Square shape panel 96 x 96mm● 3 bi-colored LED indicators for "SYNC", "GEN" and "BUS"● 24 LEDs in a circle display the phase angle and the frequency differences between 2 networks● 360° indication● 12 o'clock position LED is bi-colored● PC window, ABS resin frame, PC case
-
product
Circuit Breaker Testing
Weshine Electric Manufacturing Co., Ltd
Time measurement: 12 fracture intrinsic points, closing time, with the same period, phase with the same period.2. Reclosing measurement: each fracture closing - minute, minute - closing, minute - closing - minute process time, one minute time,one closing time, two closing time, gold short time, no current value.3. Bounce measurement: closing bounce time, bounce times, bounce waveform of each fracture, rebound amplitude of each fracture.
-
product
AC Source
AFC
The AFC Series products are single and three phase AC Power sources ranging from 0.5kVA to 2000kVA. This AFC series has a continuous and adjustable output voltage between 5~300V. This allows for quick and convenient 3 scales of preset voltage for high and low voltage simulation. Power is supplied by state-of-the-art IBGT pulse width-modulated power amplifiers resulting in highly efficient power conversion, compact design and maximized performance. With up to 90% efficiency the AFC minimizes heat dissipation so less infrastructure cooling is required.
-
product
Highly Accelerated Life (HALT) Test
HALT consists of high and low temperature and 3 axis vibration testing performed either individually or in combination.Highly accelerated life testing is performed to identify design weaknesses and problems prior to production. HALT subjects equipment to overstress conditions at a level which does affect life, but offers an advantage by reducing the design and development phases of a program.
-
product
Phase Sequence Meters
Phase sequence meter is used for detecting the sequence of the supply in three-phase electric circuits. Since the direction of rotation of three phase electric motors can be changed by changing the phase sequence of supply. And also the correct operation of measuring instruments like 3 phase energy meter and automatic control of devices also depend on the phase sequence. Different types of phase sequence testers are available in today’s market like contact or non contact, static or rotating, etc., in a wide range of voltage or power ratings.
-
product
LED synchroscope
LS-110 SYNC (110V, 120V, 220V, 230V, 240V)
Standard Electric Works Co., Ltd
• Input Voltage : 110V AC, 120V AC, 220V AC, 230V AC or 240V AC.• Standard 4.5-inch switchboard case.• Front panel mount.• 3 bi-colored LED indicators for "SYNC", "GEN" and "BUS".• 24 LEDs in a circle display the phase angle and the frequency differences between 2 networks.• 360° LED indication.• 12 o'clock position LED is bi-colored.
-
product
Brushless DC Motors
CAES offers brushless DC motors in 2 or 3 phase and with optional commutation.
-
product
Turns Ratio Meter 3 Phase
TR-MARK III 250V
The TR-MARK III 250V is the successor of the famous TR-MARK III. Besides an extended test voltage up to 250V, it offers new features and increased accuracy to make it a perfect system. A color LCD with back lighting and touch screen increases handling and user comfort. Two USB interfaces make it easy to store measurements on external storage devices and transfer easily to a personal computer or download nameplate data of transformer to test.
-
product
Phase Squence Tester
Measurement Range3 phase check for AC 90V ~ AC 600V (Sine Wave) Operation Frequency45Hz ~ 70Hz Test Time LimitationAC 110V(continuous)AC 220V(3 hours)AC 480V(12 minutes)AC 600V(3 minutes) Power Supplyno battery required Color change LED phase direction indication
-
product
RF Signal Generators
As Rigol's RF first signal source, the DSG3000 series offers standard AM/FM/ØM analog modulation, as well as options for I/Q modulation and I/Q baseband output. The instrument is available with maximum frequencies of either 3 GHz or 6 GHz. Featuring a high signal purity with phase noise measuring <-110dBc/Hz@20kHz (typical) and a wide output range of -130dBm to +13dBm, the DSG3000 RF signal generator has standard pulse modulation with an on/off ratio of up to 80dB, with optional pulse train generator available. The DSG3000 series also has an amplitude accuracy of <0.5dB (typical).
-
product
Enlarge Environmental Chamber
REXMED REC-450
MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
product
Three Phase Meter Test Bench
Supreme Instrument Laboratories
Three phase meter test bench suitable for calibration & testing of AC Ammeters, Voltmeters, Single phase Energy Meters, Watt Meters, Power Factor Meters, Three Phase Two Wire & Three Phase Four Wire Energy Meters Trivector Meters, Maximum demand indicators, of active & reactive systems, Three phase 3 wire & 4 wire watt meters, Var Meters, Power Factor Meters etc.
-
product
Digital Panel Meter
CM3-VA7
Chuan Sheng Electronics Co., Ltd.
CM3-VA7 is a multifunctional 3-phase voltage/ current meter.With 3 phase voltage or current display at the same, configurable display range via front buttons, anti-inference design, reliable quality and easy to use and install CM3-VA7 also has multiple I/O functions including 3 relay outputs, an analogue output and a RS485 communication port running the Modbus RTU Protocol.
-
product
High Resolution Oscilloscopes
PicoScope® 4000 Series
High voltage and power electronics.Single & 3 phase voltage/current.SMPS design and test.Motor drives and inverters.Hybrid and EV design.
-
product
Power Capacitor
POLB HD 7%
Lifasa - International Capacitors, SA
They are self-regenerating condensers with low loss polypropylene dielectric, filled with N2 inert gas mainly, or with resin, and with overpressure disconnection system, which offers a high level of safety against defects, when cutting the 3 phases in case of action.
-
product
Digital ELCB (RCD) Tester
1813 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● Suitable for domestic version.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Automatic data hold function.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● 60Hz available.
-
product
Three-Phase Motor Rotation Tester
MR-1A
# No need to disconnect drive shaft couplings# Identifies open windings# Protects user and equipment# Reliable, solid state components# Shirt pocket size, 48" leads with heavy duty 1/2" clips, works on most sizes and types of 3 phase motors
-
product
Relay Test Set
RNT-5A
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.
-
product
Solar Analyzers
Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability)The analyzer and the Remote Solar Detector is connected by Bluetooth wireless communication (Bluetooth 2.1 + EDR Class 1)The Remote Solar Detector is moisture-proofIntelligent test logic with no personnel attendance required in the field Solar system analyzer waits and tests the system until appropriate sunlight irradiance is detectedMax. voltage (Vpm) at Pmax, Max. current (Ipm) at Pmax Voltage at open circuit (Voc), Current at short circuit (Isc)Efficiency (%) calculation of solar systemTemperature measurement of solar panelsIrradiance measurement of sun lightSeries resistance (Rs) calculation of solar panelsWith data logging/open function, the I-V curves of solar system can be analysed / recorded for a period of time (e.g. 60 min.)Conversion of I-V curve under OPC to data under standard test condition (STC) based upon IEC standardProvide Operating Condition (OPC) and Standard Test Condition (STC) test reports for verification of solar panel performance (OK or NO OK)Users can set up the parameters of solar panelsUsers can set up the series number of solar panels. Parameters of many solar panels can be measured in one measurementThe Irradiances and Temperatures of solar panels can be continuously measured, monitored and recordedContinuously measure/monitor/record the DC power output of solar system and the AC power output of inverter (1 phase or balanced 3 phases)Calculate the efficiency of DC to AC power conversion and the efficiency of the max.output power
-
product
Regenerative AC Emulator, 600 VAC, 63 A, 45 KVA, 3‑Phase
SL1202A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Phase Indicators
Kyoritsu Electrical Instruments Works, Ltd.
New technology permits safe testing, without the need of direct contact between probes and live wires. The insulated crocodile clips can clip insulated cables from 2.4 to 30mm. Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones. The instrument can be fixed to a metal panel via the magnet on the back side. Wide measuring range for 3 phase installations from 70V to 1000V AC. Super brightness function permits clear LED''''s indication also in sunshine. Complies with IEC 61010-1 CAT IV 600V and CAT III 1000V.
-
product
RF Synthesizers
HSX SERIES
Holzworth Instrumentation, Inc.
The HSX Series are broadband frequency sources exhibit industry leading phase noise and spectral purity performance coupled with a highly accurate dynamic range of up to +20dBm and down to -110dBm. The 1U high form factor offers 1, 2, 3 or 4 channel models; all providing the ultimate in frequency accuracy, while the phase coherent RF outputs provide the ultimate in channel-to-channel stability.
-
product
Multifunction Electrical Installations Meter
MPI-525
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
product
Field Testing Equipment for 3 Phase Energy Meter
SY3002
Hong Kong Songyang Industrial Ltd.
The field-testing instrument SY3002 is made by using the newest international digital electron technical skill To use DSP processor, as the axis to install this intelligent comprehensive automation field-testing instrument, which comes with a portable computer, the 11.3" colorful display screen, and Chinese characters operation menu suggestion.
-
product
RF and Microwave Circuits Design
1. Design and implementation of RF front end receiver module. 2. Design and implementation of RF front end transmitter module. 3. Design and implementation of voltage controlled oscillator and phase lock loop. 4. Design and implementation of IF demodulator and audio process circuit. 5. Design and implementation of wireless transceiver module.
-
product
CT Tester
6000 Bird Dog Plus
Spinlab Utility Instrumentation, Inc.
This new and exciting true 3 phase Bird Dog Plus enables you to determine the accuracy of any meter in the field--from Form 1 through Form 17. Electronic sensors allow you to automate the test to gain the highest possible accuracy. The process is fast, simple, and much less expensive than a portable test board for the meter test and still perform ratio & burden tests on your CTs (CT Tester).
-
product
Audio Test Software
1. Distortion free stimulus even the equalized stimulus.2. Unlimited channels acquisition and processing. (Hardware limited)3. Human correlated listening test(Bark Scale intensity chart). (Requires large memory)4. Hi Res intensity chart for buzz/pop detection. (Requires large memory)5. Auto equalization method with target dBSPL accuracy.6. TCP client for test framework integration.7. Easy limits and logs development.8. Easy logs visualization module.9. Auto waveform alignment and triggering.(Upto single point alignment accuracy)10. Easy regression testing via TCP client.11. Standard Magnitude, Phase, THD, THD+N, Rubb&Buzz, Pink Noise, Noise Tests.12. Unlimited calibrations and equalization for scaling to different products and stations.13. Lowest test system and test sequence development times.14. Requires minimal training and debugging.15. Automatically avoid Reference speaker play and stop pops.16. WMD/ASIO driver compatible sound cards supported.(B&K 3670 recommended)