Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
LXI High Density 16x64 2A Matrix with BIRST
60-552-021
It is constructed from 8x64 sub-assemblies, permitting the matrix to be supplied in a variety of sizes from a single 16 x 64 to 64 X 64 and dual 8x64 to 32x64. Larger configurations can be easily achieved by utilizing the Loop thru connections on either the X or Y bus, for instance, four 64x64 units can be linked to create a 128x128 matrix.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
Your product description goes here.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Contact Probes
Rika Denshi Group Contact Probes - specialty probes including fine pitch testing, high frequency testing, high temperature testing, kelvin test, and high current test, as well as standard probes for 0.4mm-, 0.5mm-, 0.65mm-, 0.8mm-, and 1.0mm pitch.
-
product
TightSight™ Clamp Meter, 660A AC/DC W/TRMS
61-765
*TightSight™ bottom display*Tapered jaws with hook tip*True RMS current and voltage*AC/DC voltage*Audible continuity*High frequency rejection**Peak hold*Max/min hold*Data hold*Selectable audible and visual alerts when potentially hazardous voltages are detected at the probe terminals*Selectable auto power off*Backlit display*Low battery indicator*Reads accurately on noisy electrical circuits
-
product
High Frequency Cartridge for HFP Series Probes
PACC-MS003
High Frequency Cartridge for HFP Series Probes
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
2.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS2500
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS2500 is ideal for 2.5 GHz and lower oscilloscopes.
-
product
High Voltage Differential Probes
High voltage differential probes provide high CMRR over a broad frequency range (up to 400 MHz) to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
product
500 MHz Passive Probe for WaveJet Touch, 10:1, 10 MOhm
PP006D
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
High-Frequency Probe, 300 kHz to 3 GHz
85024A
85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of RF analyzers.
-
product
High Frequency/Microwave
SemiProbe high frequency probing solutions provide a broad array of capabilities for measurements ranging from DC to over 300 GHz. We design PS4L systems for high frequency applications with carefully selected components including chucks, probe arms, probes, cables, tuner modules, and calibration suites that are optimized for the frequency range that the application will operate in.
-
product
Combination Board Tester
V250 / V250PXI
Qmax Test Technologies Pvt. Ltd.
V250 / V250PXI is designed as a Combination Board Tester capable of testing highly complex and dense PCBs employing various test techniques on a single platform. It can perform Board Level Functional Test through edge connectors of a PCB, and guided probe diagnostics utility to reliably repair Digital/Analog and Mixed Signal PCBs of various complexities and conventional PCBs. An In –Circuit device test by configuring Pin Drivers to High Current Pin Driver mode and interface to the UUT either through Clips / Probes or nail bed and on board clock disable HW feature are the all time favorite . The in-built high frequency 14bit Analog Driver / sensors synchronized with digital drivers for covering analog / mixed signal devices with high degree of accuracy.
-
product
Passive Probes
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
High Flexibility VNA Cables
Our lines of high frequency VNA test cables display excellent electrical properties such as wonderful phase stability of +/- 6° at 50 GHz and +/- 8° at 67 GHz as well as VSWR of 1.3:1 at 50 GHz and 1.4:1 at 67 GHz. The 50 GHz assemblies are terminated with 2.4mm connectors while the 67 GHz versions utilize 1.85mm connectors. The braided stainless steel armoring surrounding the coax provides a rugged, but flexible cable with a flex life exceeding 100,000 cycles, making these test cables ideal for use in semiconductor probe testing, precise bench top testing as well as lab/production testing where the need for a highly flexible, yet durable cable solution is required. The VNA test cables are also equipped with rugged stainless steel connectors that provide up to 5,000 mating cycles when attached with proper care. Additionally, the flexibility of these cables makes it easier and safer to test a Device Under Test (DUT). A swept right angle 2.4mm and 1.855mm connector option allows these cables to fit in tight spaces and can reduce the length of cable required in many applications.
-
product
Vector Network Analyzer Extenders
VNAX
VDI''s VNA Extenders deliver high performance network analyzer frequency extension into the THz range. Models cover 50 GHz to 1,100GHz with additional bands in development. VDI modules come in a variety of form factors and configurations including our original Standard-size Modules and new Mini Modules that reduce volume up to 75%. In addition to our full Transceiver (TxRx) modules, VDI also offers Transmit-Reference (TxRef) modules and Receive only (Rx) modules that deliver optimized performance for specific applications. These modules combine high test port power and exceptional dynamic range to deliver industry leading performance. They are compatible with most network analyzers and can be integrated into probe stations and antenna chambers.
-
product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Passive Probe
PP011-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Rotating Bolthole Scanners
Nortec
Olympus extensive line of high performance eddy current scanners is available for use with Nortec Eddy Current Flaw Detectors. With a wide range of features consisting of speed ranges from 600 to 3000 rpm, frequency ranges from 100 Hz to 6 MHz, multiple connector types, and multiple probe types, our scanners offer a full range of application solutions.
-
product
High Voltage Passive Probes
The PPE6KV-A and HVP120 can handle up to 6000 Vpeak transient overvoltages and are designed for probing up to 2000 Vrms and 1000 Vrms respectively. Fast rise times, excellent frequency response, and a variety of standard accessories make these probes safe and ideal for high voltage measurement applications
-
product
Test & Test Development for Circuit Card Assembly
Teledyne Advanced Electronic Solutions performs comprehensive testing at the CCA and system level assembly. Teledyne AES can perform testing developed by the customer or develop a complete test strategy for the customer’s products.- Bed of Nails FixtureIn-Circuit Test (Bed of Nails) or Flying Probe Testing for rapid feedback on CCAs- Functional testing of CCAs or complete systems- Environmental testing to include vibration, thermal cycling, HASS, etc.- CCA and system level test development- High frequency testing – currently to 40 GHz- High power system testing – currently to 4kW
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
product
EMF Testers
TES Electrical Electronic Corp.
Frequency range 10MHz to 8.0 GHz3 axis isoltropic measurements of EMFNon-directional measurement with three channel measurment probe. High dynamic range.Configurable alarm threshold and memory function.