Filter Results By:
Products
Applications
Manufacturers
-
product
Charge Sensitive Preamplifier-Discriminator
A101
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
product
Digital Multi Channel Analyzer
DT5770
The DT5770 is a compact portable 16k Digital MCA for Gamma Spectroscopy, integrating analog front-end with programmable gain and possible AC coupling. It is ideally suited for high energy resolution semiconductor detectors, like HPGe and Silicon, connected to a Charge Sensitive Preamplifier (CSP). The unit can also properly operate directly connected to a PMT with inorganic scintillators (e.g. Nal or Csl scintillators), provided exponential pulse shape and decay time above 200 ns.
-
product
Preamplifier
2721
Pre-amplification is required to protect the output signal of pH and ORP electrodes from a wide variety of electromagnetic interferences common in industrial environments. Signet 2721 is used if remote pre-amplification is required (e.g. tank temperature >80oC) or connecting another manufacturer's electrode to the Signet 5700 or 8750 instrument. The Signet 2721 should be used with special order sensors built with cables (Signet models 277X-HT or 277X-1-HT).
-
product
Preamplifier
The UBBV series are external, extremely low-noise broadband preamplifiers that can be mounted to any SPECTRAN spectrum analyzer. They are ideally suited for spectrum analyzers and oscilloscopes as well as antennas of all manufacturers and are supplied with extensive accessories.
-
product
Preamplifier
Is designed for the amplification of measuring signals, e.g. weak signals of near field probes with high resolution.
-
product
Preamplifiers
Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.
-
product
Preamplifiers
A.H. Systems'' Preamplifier line is an excellent choice with a rugged design, no hassles with soldering your own power leads and they improve overall system sensitivity by at least 20 dB. All of A.H. Systems'' Preamplifiers come with a 12-volt (or 15-volt) DC regulated power source. A low voltage indicator confidently allows you to power the amplifier with your own external 12-volt DC battery. This makes it a convenient choice for field measurements. See table below for amplifier specifications.
-
product
Preamplifiers
LNA Series
Low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments. All measuring instruments have a 'noise figure', which is a measure of how good the instrument is at measuring low level signals, the lower this figure, the better, although the lowest signal level will still be governed by the measurement bandwidth. A typical spectrum analyzer may have a noise figure of 20 dB or more, whereas a typical receiver may have a noise figure of 10 dB. The preamplifier has a noise figure of typically 4 dB, significantly enhancing the low level performance of such instruments, enabling signals that were previously masked by noise to be seen.
-
product
Preamplifiers
Is an electronic amplifier that converts a weak electrical signal into an output signal strong enough to be noise-tolerant and strong enough for further processing, or for sending to a power amplifier and a loudspeaker.
-
product
Preamplifiers
Preamplifiers recognize the extremely low amplitude AE signal produced from AE sensors, and convert the signals into amplified and usable forms. As applications and testing conditions vary, project needs may change as well. Physical Acoustics offers an entire line of preamplifiers for a variety of testing requirements. Operating in conjunction with our specialized AE software, preamplifiers also moderate signal size during the data collection process, helping to produce accurate results.
-
product
Preamplifiers
The primary function of a preamplifier is to extract the signal from the detector without significantly degrading the intrinsic signal-to noise ratio. Three basic types of preamplifiers are available: the current-sensitive preamplifier, the parasitic-capacitance preamplifier, and the charge-sensitive preamplifier. ORTEC manufactures a preamplifier to fit your detector, your application, and your budget.
-
product
Pre-Amplifiers
MPR, MDA series
MPR, MDR series provides low noise, high gain and wideband to improve dynamic range for emission testing. We also offer customized model for variable requirments.. Example 30M-1000MHz with band-pass filter Amprifier unit for connecting antenna directly
-
product
Time Sensitive Networks
Time Sensitive Network (TSN) standards enable deterministic real-time communication over Ethernet, allowing solutions to be built to provide extremely precise, predictable timing and control across the network. By adding features to Ethernet such as time synchronization, ingress policing, seamless redundancy, frame preemption, scheduled traffic, and stream reservation, TSN ensures data is not delayed by the network.
-
product
Charge Amplfiers
Trik-TekTM Line
Astronics offers the Trik-TekTM line of charge amplifiers, available in a variety of configurations for your application.
-
product
Charge Amplifier
CH-1200A
CH-1200A is a high-performance charge amplifier to convert charge signal to voltage signal. Built-in integration function allows optimization of the signal which is input to the vibration data analyzer connected.Changing into a multi-channel amplifier is easy by connecting multiple units.
-
product
Charge Amplifier
This compact Charge Amplifier has 3 signal routes.When it is used as the Charge Amplifier for the vibration analysis systemWave Stocker, all setups are possibleby the upgraded software.
-
product
Charge Amplifier
ZET 440
Charge amplifier ZET 440 for piezoelectric detectors is intended for:*amplification and conversion of output signals of primary piezoelectric transducers with charge output;*amplification and conversion of output signals of primary transducers with the IEPE type in-built electronics to voltage;*gain ratios: 1, 10, 100;*LPF: 0.1, 1, 10 Hz
-
product
Charge Controller
The intelligence of an AC charging station or an AC charging infrastructure is largely determined by the charge controller used. A smart charge controller has the primary task of controlling and monitoring the charging process of an electrical vehicle.The features that characterise a smart charge controller include communication with a backend system and the associated authorisation of users, as well as the efficient distribution of load currents by means of dynamic load management to prevent an overload of the existing AC system.
-
product
Charge Converter
CH-6130/6140
The CH-6130/6140 charge converter is a simplified type of charge amplifier converting charge signal to voltage.It can be connected directly to an input BNC connector of a CCLD applicable equipment such as FFT analyzer or vibration comparator, enabling direct connection of a charge output pickup without suing a box type amplifier.
-
product
Charge Meter
NK-1001A/NK-1002A
Probe-type charge meter that can easily measure the amount of discharge charge that causes static electricity destruction in the manufacturing, inspection, and assembly processes of electronic devices.Many ESD phenomena that impair electronic devices are represented by the CDM ( Device Charging Model). The CDM is a model that represents a phenomenon in which a high peak current flows at high speed when the device itself is charged and its external electrode is grounded. The coulomb meter measures the amount of discharge charge, which is the integral value of the current, with high accuracy.
-
product
Charge Pumps
Renesas offers monolithic CMOS voltage conversion ICs that perform supply voltage conversions from positive to negative for an input range of 1.5V to 12V, resulting in complementary output voltages of -1.5V to -12V.
-
product
Current Preamplifier
1212
The Model 1212 Current Preamplifier is designed as a low cost, gerenal purpose, benchtop instrument to provide a high performance detection system for small ac and dc currents. The 1212 operates with a virtual ground at its input which mitigates unpredictable high frequency rolloff due to input cables and stray capacitance.
-
product
Current Preamplifier
1641
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
product
Current Preamplifier
1211
The model 1211 Current Preamplifier was designed to provide all of the features required of a modern laboratory preamplifier. It measures cur rents with full scale sensitivity ranging from 10 to 10 amperes.
-
product
External Pre-amplifiers
Although all Spectrum A/D cards have a very powerful input section with a highly configurable input amplifier and a variety of input ranges it is sometimes necessary to have additional external amplifiers if the signal to acquire has an extremely low level. Spectrum offers a range of perfectly matching external amplifiers to cover such cases. These powerful amplifiers have been rated using the Spectrum cards and offer best performance together with high amplification rates.The amplifiers are simply connected between the signal source and the Spectrum A/D card input and can be manually switched between different settings using small lever keys. All amplifiers allow the offset compensation by using an adjustable screw.
-
product
Microphone preamplifier
PRE-01
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
product
Microphone Preamplifier
426A30
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
product
Microphone Preamplifier
426A11
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
product
Microphone Preamplifier
426B31
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes