Hydrogen Maser Frequency References
Microwave Amplification by Stimulated Emission of Radiation
See Also: Atomic Clocks
- PJ Electronics, Inc.
product
Digital High Frequency Surge Testers
C Model
These Digital High Frequency Surge Testers are the ultimate in ruggedness & durability. Fourteen / sixteen gauge steel construction and mobility on 6" heavy duty rubber wheels makes it a favorite for use in harsh industrial environments. The performance of PJ's exclusive/unique High Frequency Technology is capable of testing the integrity of any turn-to-turn insulation, including low inductance windings.
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX02
The N5295AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
K-50 Series Probes
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
110 GHz Frequency Extender
N5293AX03
The N5293AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Smart Active Hydrogen Maser Clock
iMaser 3000™
The iMaser 3000 clock is a state-of-the-art, high-performance and smart maser, integrating intelligent functionality in a compact, cost-effective and maintenance-free package.
-
product
110 GHz Frequency Extender
N5293AX53
The N5293AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Hydrogen Frequency & Time Standard
CH1-1007
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.
-
product
Frequency Reference
Quartzlock time and frequency standards offer a complete range of cost effective and low noise in both atomic controlled (rubidium oscillator) and GPS controlled (off-air) time and frequency reference, calibrators and standards. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
product
Shaper Of The Reference Frequency
MFC
The mezzanine module (mezzanine) of the MFC is designed to reproduce on six output lines high-precision frequency values obtained by dividing the frequency from the built-in reference frequency generator.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
Your product description goes here.
-
product
3207a GPS/GNS Frequency and Time Reference
GlobalTyme2
Precise Time and Frequency, Inc.
The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.
-
product
Oxygen/Nitrogen/Hydrogen Analyzers
EMGA-Pro
The characteristics and performance of metal and solid materials, including steel, various other metals, ceramics, and electronic materials, are determined by the amount of oxygen, nitrogen, and hydrogen. Analyzing elements in such materials at high accuracy and with a small amount has become increasingly important in the study and performance analysis of materials. The EMGA Series Oxygen/Nitrogen/Hydrogen Analyzers significantly reduces analysis time and costs while enhancing analysis accuracy and functionality. Pursuing also usability, the EMGA Series strongly supports improved efficiency in material research and development and quality control.
-
product
3207a GPS/GNS Frequency and Time Reference
Precise Time and Frequency, Inc.
The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.
-
product
Hydrogen Frequency & Time Standard
CH1-1006
The hydrogen frequency and time standard Ch1-1006 is designed to generate highly stable, high-frequency, spectrally pure sinusoidal 5, 10, 100 MHz and pulsed 1 Hz signals and for the behavior of time-frequency measurements.
-
product
Hydrogen Frequency & Time Standard
CH1-1035
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
product
Reference Sources
A physical or digital document that you would refer to for more information about a topic.
-
product
Reference Solutions
As you seek solutions to evolving test challenges, Keysight Reference Solutions provide the right combination of hardware, software, and measurement expertise through programming examples highly optimized for specific applications. Reference Solutions show you how to get the most out of your test equipment, helping you achieve half the time to insight.