Filter Results By:
Products
Applications
Manufacturers
-
product
Electrodes
EGL electrodes have consistently raised the industry standards for reliability and performance since their introduction in 1930.To ensure rigid quality control, all phases of manufacturing are performed in-house, including emission coating, inverter welding shells with lead wires, and sealing and centering the mounts in glass envelopes.
-
product
Electrodes
Electrodes are offered in a wide variety of types. Spring electrodes are normally used in the inspection of pipes, although circular brush electrodes can also be used. Flat brush electrodes are used for flat surfaces. Brush materials can be of brass, steel or conductive neoprene construction. Internal electrodes are for testing internal pipe coatings.
-
product
Electrodes
Delmhorst offers a wide assortment of electrodes known throughout the industry for their durability. All Delmhorst electrodes fit any Delmhorst moisture meter.
-
product
Grid Electrode
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
product
IDA Electrodes
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
product
pH Electrodes
A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies.
-
product
pH/ORP Electrodes
2734-2736
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life.
-
product
pH/ORP Electrodes
2724-2726
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc connector. The large area PE reference junction and pathway is constructed to increase the total reference effectiveness and ensures long service life.
-
product
Cells and Electrodes
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
product
Conductivity Electrode
As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.
-
product
Conductivity-Resistivity Electrodes
2818-2823
Signet Conductivity/Resistivity electrodes are designed to provide versatile installation and accurate sensing across a very broad dynamic range. These electrodes are built with a controlled surface finish to ensure accuracy and repeatability. The standard electrode is constructed 316 SS or Titanium, but there are other materials available for maximum chemical compatibility.
-
product
Counter Electrodes
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
product
Electrode Holder
HD22.2 - HD22.3
HD22.2: Laboratory electrode holder composed of base plate with built-in magnetic stirrer, shaft and replaceable electrode hold-er. Suitable diameter 12 mm. It holds up to 5 electrodes at the same time. Powered by power supplier SWD10 (optional). HD22.3: Laboratory electrode holder composed of base plate. Flexible arm for free positioning. Suitable for electrodes with diameter 12 mm. It holds up to 5 electrodes at the same time.
-
product
Electrodes Sensor
6013
When selecting electrode sensors an important factor is to consider the specific characteristics of the liquid involved, the lengths required to obtain the desired control of levels, and the physical nature of the container.B/W Controls' line of electrodes has been developed to provide a practical, economical solution to almost every conceivable application and installation problem.Our electrode sensors are available in several varieties: solid rod (rigid), wire suspension, and standard gland plugs for high vibration applications. In addition, we offer custom options made per customer’s requirements.
-
product
Starter Electrodes
Backed by our commitment to accurate and precise measurement, the OHAUS Starter Series of electrodes are designed to produce exact results time and time again.
-
product
Meter with Electrode
TDS 6+
Automatic or Manual Calibration - for quick, easy calibration; use automatic mode with preset calibration points at most popular values or manually set values in the manual mode for more flexibility
-
product
Reference Electrodes
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
product
High-Temperature and High-PressurepH Electrodes
UltraDeg
Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).
-
product
pH Electrode Holder
PF12
Extension of optek sensor bodies for inline pH measurement in industrial installations of various applications. Commonly available Ø 12mm & 120 mm length pH probes can be used and are positioned at an optimum angle into the process stream.
-
product
Electrode Measurement Meter
Ion 700
Ion-selective electrode measurement has never been this easy – or economical! The Ion 700 measures and records up to 100 data points with 0.01 resolution.
-
product
Reference Electrode Kit
SC-4
The Model SC-4 Sliver-Silver/Chloride kit come complete with everything necessary to conduct field tests both ON SHORE and OFF SHORE.
-
product
Ring Disk Electrode
This ring-disk type electrode developed by NTT Advanced Technology Corporation is a form of printed electrodes. Users can choose them from Carbon, Gold and Platinum applied versions. Available as a working electrode of radial flow cells, achieves complete reduction/oxidation on the center disk at ultra-low flow rate because of its fine coulometric electrolysis efficiency. This also enables to analyze subsequent reaction as well as identification and quantitation of the sample at the same time.
-
product
Salinity Meter with Electrode
Salt 6+
Automatic Temperature Compensation (ATC) for the optimum accuracy under fluctuating temperatures :: Hold Function momentarily freezes reading for easy viewing and recording
-
product
PVDF Conductivity-Resistivity Electrodes
2839-1V(D)-2842-1V(D)
The Signet 2839-1V(D) to 2842-1V(D) Conductivity/Resistivity Electrodes are available in four cell constants from 0.01 to 10.0 cm-1, and are suitable for a wide variety of applications from high purity water quality monitoring to weak acids and bases. 316 SS electrode surface finishes are controlled in a precision bead blasting operation to ensure measurement accuracy and repeatability.
-
product
Meter w/ pH Electrode, Conductivity/ATC Probe, Integral Electrode Holder
PC 700
The multi-parameter Eutech PC 700 measures pH, ORP, conductivity and temperature with a single meter. User-friendly with advanced features and a large custom-size display – perfect for research work on a budget!
-
product
pH Testr with Spear Electrode
pHSpear
Unique pHTestr with spear electrodepH is one of the key parameters measured in food processing. The Eutech waterproof pH Spear with tough, spear tip open pore sensor is a rugged, user-friendly tester ideal for direct measurement of solid or semi-solid samples such as cheese, meats, fruits, bread and other similar samples.
-
product
5lb Conductive Rubber Electrode
PRS-801W
Probe to test resistance of floors, worksurfaces, floor mats, or other flat objects.
-
product
Solid Electrode Spectrochemical Cell
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
product
Threaded DryLoc pH/ORP Electrodes
2774-2777
The Signet 2774-2777 pH and ORP Electrodes feature a unique foulproof DryLoc connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 preamplifiers and sensor electronics. These dependable and highly responsive electrodes feature a PTFE double reference junction with KNO3 in the front chamber to block various poisoning ions.
-
product
Water Analysis Meters & Electrodes
Ideal for Accurate Everyday Measurements in the Laboratory