Filter Results By:
Products
Applications
Manufacturers
I²C
A slow Inter-Integrated Circuit bus protocol.
-
product
I²C/SPI Interface Device
The I²C/SPI Interface Device is a master or slave interface for inter-integrated circuit (I²C), or master interface for serial parallel interface (SPI) devices. With plug-and-play USB connectivity, the I²C/SPI Interface Device is a portable solution to communicate with consumer electronics and integrated circuits. The I²C/SPI Interface Device can be physically located more closely to I²C/SPI devices than PCI interfaces, reducing I²C bus length and minimizing noise problems. The I²C/SPI Interface Device supports I²C rates up to 250 kHz and SPI rates up to 50 MHz, and it also includes eight general-purpose digital I/O lines for a variety of applications, such as configuring the address of I²C devices or toggling LEDs.
-
product
NI-9209 , ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
785042-01
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
product
NI-9209, ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
783729-01
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
product
NI-9220, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Modul
782615-01
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at … the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
product
NI-9220, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module
782615-02
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
product
NI-9220, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module
785188-01
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
product
Hazardous Location Syringe Pump
1000HLf
The Teledyne ISCO HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.
-
product
Hazardous Location Syringe Pump
100HLf
Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.
-
product
Hazardous Location Syringe Pump
260HLf
Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.
-
product
Hazardous Location Syringe Pump
500HLf
The Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.
-
product
Impulse Tester
MIG2412SPD
The MIG2412SPD is a impulse tester for testing SPD (Surge Protection Devices) in accordance with IEC 61643-1 and VDE 0675. Up to maximum 24kV/12kA making it suitable for testing Class I to III or in accordance with VDE Class A,C, D. The MIG2412SPD is a hybrid generator with a voltage wave shape 1,2/50 ìs at "no load" and a current wave form 8/20 ìs at short circuit for testing Class III (D) SPD connected to power line.
-
product
Incubator
I
In the laboratory, the Memmert incubator I is ideal for all applications with temperatures up to +80C specifically for incubating living cultures at +37 C. Thanks to the finely-tuned control technology, critical temperature overshoots are completely ruled out, valuable loads are therefore warmed up particularly carefully in this highly precise microbiological incubator.
-
product
I/O Expanders and Level Translators
ST’s Xpander family of general-purpose input/output port expanders are used to interface digital ASICs via a two-line bidirectional bus (I²C) . ST’s dual-supply level translators are used as interface between multi-voltage chipsets and system I/Os, ranging from 5.5 V down to 1.2 V.
-
product
NI-9220, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle
865685-01
NI-9220, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9220, cDAQ-9171, and cRIO-9940 includes the NI-9220 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9220 features 16 channels and 16 simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. Additionally, you can use the NI-9220 to generate 3.2 MB/s of data at the maximum sampling rate.
-
product
Osmometer
LD-LOSM-A10
OsmometerLD-LOSM-A10is colorful LCD touch display with sample size 50 μl to 100 μl and measuring range up to 0 to 3000 mOsmol /kg H2O at ambient temperature 10 to 30°C. Features with on-screen display of molar concentration, freezing point, and osmolarity. At very low testing time it provides fast and accurate osmolality test results. Applicable in General medicine, Routine and research, Forensic medicine, Electron microscope.
-
product
PMC FPDP Board
MS 1741
- Four FPDP front panel outputs- FIFO buffering for real−time recording- FPDP Outputs: Two 80−pin FPDP connectors (A and B)- FPDP Outputs: Two 80−pin FPDP connectors(C and D)- Quantity: Standard: Two Front Panel Data Port (FPDP) connectors, each providing 32−bit output- Output Type: FPDP I, non−inverted configuration FPDP II, double the selected clock rate- Clock: On−board clock- FIFOs- Quantity: Four IDT72V3690 FIFOs, one for each FPDP port- Size: 32,768 x 36- Speed: FIFOs are capable of 166 MHz speed, but are run at one half of sample clock speed
-
product
Block Up-Converter
BUC Series 5” x 2.5” x 0.6”
*Connectorized Package *Compact, Rugged Design *C, X, Ku, K, and Ka-Bands Available *L-Band Inputs (950-2150 MHz) *Internal or External Filters Available *Variable Attenuation Control via CAN +5V Logic, SPI, RS232, or I²C
-
product
Bus Analyzer, Exerciser, Emulator, and Programmer
CAS-1000-I2C/E
While the I²C interface seems simple on the surface, this straightforward architecture is not immune to intermittent glitches, device misbehaviors, and protocol violations. Likewise, tracking down these errors can be tedious business if the right tool is not utilized.The CAS-1000-I2C/E bus analyzer is an exceptional tool for pinpointing I2c irregularities. The ability to spot complex problems and identify invisible obstacles make it the preferred I²C development solution. Advanced logging, debugging, emulation, and verification capabilities offer power and versatility, yet the Windows-based user interface makes the most complex features simple to use.The CAS-1000-I2C/E succeeds where simple monitoring and interactive I/O tools fall short—a complete solution to monitoring, emulating, stressing, and characterizing I²C and SMBus interfaces.
-
product
Bus Analyzer, Monitor, Debugger and Programmer
BusPro-I
In the world of rapidly accelerating product development cycles, engineers developing products which utilize the I²C and SMBus interfaces need a bus analyzer that is easy to use—fast and simple.Unforeseen problems such as functional bugs can cause schedules to slip so it is important to have the right tool to resolve them quickly by isolating the root cause.The Corelis BusPro-I analyzer is designed with that idea in mind—the right tool at the right price. Open the box and plug it in; everything just works.
-
product
Calibration Services
Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. We have calibration laboratories at Vadodara (Temperature Range for Contact Type Sensors -196 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C) and Bangalore (Temperature Range for Contact Type Sensors -35 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C).
-
product
Embedded Analysis Software for the 2000 X-Series
D2000GENB
Test and debug I²C, SPI, RS232/422/485/UART designs with triggering, decoding, and pass / fail mask limit testing.
-
product
Explosion-Proof Differential Pressure Switch
1950G
The Model 1950G Explosion-Proof Switch combines the best features of the popular Dwyer Series 1950 Pressure Switch with the benefit of natural gas compatibility. Units are rain-tight for outdoor installations, and are UL listed for use in Class I, Groups A, B, C, & D; Class II, Groups E, F, & G and Class III atmospheres, ATEX for EExd IIB & Hydrogen T6, and CSA & FM approved for Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F, G and Class III atmospheres
-
product
Fixed Gas Detectors
MicroSafe 500 & 600 Series
Teledyne Gas & Flame Detection
MicroSafe 500 and 600 Series gas detectors feature a non-intrusive operator interface. Calibration and programming instructions appear in simple intuitive and sequential script on a 16-character backlit display. The transmitter design incorporates extensive fault diagnostics with each condition conveniently identified on the transmitter display.The 500 Series comes standard with a linear 4-20 mA output, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault and calibration status.The 600 Series includes the same features as the 500 with the addition of 3 alarm relays and an RS-485 serial communications port.Electrical Classification - Explosion proofClass I, Div 1, Groups B, C, D
-
product
SparkFun SAMD21 Development Board
Qwiic Micro
Looking for a super small microcontroller to use with the Qwiic eco-system? The SparkFun Qwiic Micro is molded to fit our standard 1"x1" Qwiic standard size which makes it one of our smallest micro-controller offerings to date. At it's core is the powerful and versatile ATSAMD21E18, which is an ARM Cortex M0+, 32-bit microcontroller, with 256KB of flash memory that can run at up to 48MHz! It has 12 digital pins which include 5 analog pins, SPI, I²C, and an additional UART data bus as well as a Qwiic connector for easy integration into the Qwiic ecosystem and I²C prototyping.
-
product
Speed Sensor Intrinsically Safe
ST420
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected • Works with Electro-Sensors magnetic pulser discs / wraps Rugged stainless steel M18x1 housing; UL listed, Intrinsically Safe (IS); Class I, Div I (C, D) Class II, Div I (E, F, G)
-
product
Speed Switch
UDS1000
Features • Works with remote / external quadrature pulse frequency output sensor / incremental encoder (NPN or PNP) • DPDT relay changes state when shaft direction reverses • Reverse-over-speed setpoint adjustment from 0.5-5,000 rpm • Relay resets when reverse motion stops • 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options • Explosion proof/NEMA 4X housing • UL Listed Class I, Div I (C, D) Class II, Div I (E, F, G)
-
product
Speed Switch
SCP1000/SCP2000
Features• Internal sensor• Over-or under-speed config., 1-990 rpm• 1 DPDT relay output (SCP1000), 2 SPDT relay outputs (SCP2000)• Built-in start delay• Dial-in calibration does not require power• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options• Works with Electro-Sensors magnetic pulser discs / wraps• Explosion proof housing• UL Listed Class I, Div I (C, D) Class II, Div I (E, F, G)
-
product
Speed Switch
M100T/M5000T
Features• Internal sensor• SPDT relay output• 5-100 rpm (M100T), 100-5,000 rpm (M5000T)• Terminal block for easy wiring• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options• Works with Electro-Sensors magnetic pulser discs/wraps• Explosion proof (XP) housing• UL Listed Class I, Div I (C, D) Class II (E, F, G)
-
product
Speed Switch
DR1000
Features • Works with remote / external pulse frequency output sensor (NPN, PNP, or Mag Pick-up) • DPDT relay output • Under-speed setpoint adjustment from 0.5-5,000 rpm (at 8 PPR) • Terminal blocks for easy wiring • 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options • Rugged explosion proof / NEMA 4X housing • UL Listed Class I, Div I (C, D) Class II, Div I (E, F, G)
-
product
Temperature Sensors
TT420
Features • 2-wire, loop-powered 4-20mA analog output • Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner • Compatible with PLCs, meters, and data acquisition systems • No user calibration • TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap • TT420F mounts onto any flat surface • UL listed, Intrinsically Safe (IS) • Class I, (C, D) and Class II, (E, F, G)