Filter Results By:
Products
Applications
Manufacturers
-
product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
784170-01
The PCB HSTA15 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTA15 features a sensitivity range of 10 mV/g and requires a 4-socket plug-to-3 BNC plug cable.
-
product
Low Outgassing ICP® Accelerometers
Low Outgassing ICP® (IEPE) Accelerometer Types & Their Applications.
-
product
Dual-Mode Charge Amplifiers
Dual-mode charge amplifiers represent a versatile solution for both piezoelectric charge mode and ICP® sensors. Among the advanced features offered by models 443B01, 443B02 and 2775C are an ultra-low noise floor, sensor fault detection, overload detection, a built-in calibration reference signal, and an RS-232 port for seamless computer control. Notably, model 443B02 features a long discharge time constant selection, ideal for capturing quasi-static events lasting several seconds, a capability particularly beneficial for ballistics and ammunition testing applications. Model 2775C features AC, DC, and servo outputs.
-
product
IEPE Triaxial Accelerometer – 10 mV/g
HDP356A02
Triaxial accelerometer miniature for hand-arm measurement, ICP, 10mV/g, weight 4g, range 500 g pk
-
product
Desolvating Nebulizer
Aridus3
The CETAC Aridus3 Desolvating Nebulizer System is a specialized liquid sample introduction accessory for inductively coupled plasma mass spectrometry (ICP‑MS). The Aridus3 can enhance analyte sensitivity up to 10 times or more and can greatly reduce solvent-based interferences such as oxides and hydrides.The Aridus3 couples a low-flow (50, 100, or 200 µL/min) PFA nebulizer and a heated PFA spray chamber with an inert fluoropolymer membrane. This combination provides enhanced analyte sensitivity while reducing solvent based interferences such as oxides and hydrides. The Aridus3 is particularly advantageous for small volume and highly corrosive samples such as those generated in the earth sciences and the semiconductor industry.
-
product
In System Programmers
In-circuit serial programming, also known as in-system programming (ISP) or in-circuit programming (ICP) enables programming and reprogramming of microcontrollers, serial EEPROMs and flash memories already soldered on a target PCB.
-
product
ICP Microphone System
378C01
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
product
Compact Autosampler
ASX‑280
Users call CETAC Autosamplers the best on the market, and it’s easy to see why. Put the most reliable, efficient and solidly built autosampler to work in your lab for sample analyses. We have a model to meet your needs, regardless the size of your lab or your specific technique, whether AA, ICP, ICP-MS, TOC, US-VIS, flash/prep chromatography, protein purification, liquid handling or others.
-
product
Ballistic Pressure Sensors
PCB® has supplied high frequency, durable, quartz ballistics pressure sensors in both charge and ICP® voltage mode versions for over forty years. Keeping with our tradition, PCB continues to offer a complete line of sensors for conformal and case mouth ballistic measurements. All PCB sensors are provided with NIST traceable calibration. For pre-calibration stabilization purposes, all ballistic pressure sensors are hydraulically cycled at high pressures and most are test fired in the PCB ballistic firing range.
-
product
Off-line Automated Liquid Handling Station
SimPrep
- Wide range of syringes from 10 μL to 50 mL- A single system can serve multiple techniques such as ICP-MS, ICP, AA, Colorimeter, IC, FIA- An extra autosampler - easily switch between sample prep and sample analysis with a switching USB hub (see below).
-
product
Cryogenic ICP® Accelerometers
Cryogenic ICP® accelerometers are specifically designed to operate at temperatures below the typical -65 ºF (-54 ºC) temperature limit of most voltage mode sensors. The use of specialized, built-in, cryogenic circuitry and quartz shear sensing technology promote survivability in demanding environments such as liquid nitrogen. Each sensor is hermetically sealed and individually tested to determine the thermal coefficient of sensitivity at -320 ºF (-196 ºC) ensuring reliable operation and accurate measurements. These sensors have been successfully used in the presence of liquid helium during structural testing of rocket boosters.
-
product
Signal Conditioning Instrumentation
Columbia Research Laboratories
Columbia offers a wide variety of Signal Conditioning Instrumentation for a variety of Sensor types. These range from Laboratory as well as Airborne Charge Amplifiers, Differential Charge Amplifiers, In-Line Charge Converters, Constant Current Power Supplies and ICP Compliant Amplifiers all in support of Columbia's extensive Piezoelectric product line. Additionally Columbia offers unique Strain Gage Instrumentation Amplifiers which provide built in auto zeroing of gage offset voltages which can increase typical measurement accuracies. These robust Signal Conditioning products have been flight qualified on many current military aircraft and missile programs and are now available for your distinctive program needs.
-
product
Multitype ICP Emission Spectrometers
ICPE-9800 Series
Due to their high detection sensitivity down to ppb levels, ability to analyze a broad 5 to 6-digit range of concentrations, and ability to measure multiple elements simultaneously, ICP emission spectrometers are used in a broad range of fields, such as environmental testing, pharmaceuticals, foods, chemicals, and metals. ICPE-9800 Series of simultaneous ICP atomic emission spectrometers are next-generation systems that offer the superior accuracy necessary to simultaneously and quickly analyze multiple elements regardless of their concentration levels. They also feature user-friendly software that makes analysis easy. Furthermore, the systems reduce analysis costs while providing the highest performance levels in the industry. ICPE-9800 Series systems represent the ultimate in ICP atomic emission spectrometry for environmental, pharmaceutical, food, chemical, metal, and other fields.
-
product
Quartz ICP® Links
Link-style sensors measure dynamic compression and tension. They are constructed using a force ring that is under compressive pre-load between threaded mounting hardware. The threaded mounting on both ends of the sensor supports integrated link-style installations. Versions offering full-scale measurements of 10 lb to 50k lb (45 N to 220k N) compression and 30k lb (130k N) tension are available.
-
product
Programmable Signal Conditioning
DTX 5000 Series
The DTX-5000 Signal Conditioner Series provides up to 64 channels of state-of-the-art signal processing in a compact (5U) chassis. Using hybrid mixed-signal technology, high-performance analog circuitry is combined with Digital Signal Processing to give gain accuracy performance previously available only in larger customized modules. A simple-to-use graphical user interface running under the Windows 2000 operating system allows for ease of setup and either local or remote operation as a network-based instrument node. The suite of conditioner modules include a strain amplifier with internal bridge completion, a general-purpose instrumentation amplifier with selectable AC or DC coupling, a linearized thermocouple amplifier with cold-junction compensation, a frequency-to-voltage converter with dual inputs for direction sensing, and an ICP accelerometer amplifier with constant-current excitation.
-
product
Structural Test ICP® Accelerometers
Conventional structural test data systems use few to several hundred sensors. Cables bundles can be complex and confusing resulting in setup errors. Sensors with TEDS (Transducer Electronic Data Sheet) allow for an internal sensor digital chip to store sensor information. This information contains descriptive identifiers that when connected to a TEDS compatible signal conditioner or data system, reads the descriptive information and automatically aligns the data system. Human error is minimized, reducing time consuming data verification or re-test. The Series 333 ICP® accelerometers, and their accessories, are designed to address the needs of multi-point modal and structural test measurement applications. This equipment was developed in conjunction with the world renowned University of Cincinnati Structural Dynamics Research Laboratory and proven in real-world testing situations. The PCB 333 Series accelerometers delivers rapid system setup, reduces human documentation errors, maintains calibration data of each sensor, allows for “Plug-and-Play” installation, reduces overall test time lowering project test costs.
-
product
IEPE Monoaxial Accelerometer – 100 mV/g
HDP352C34
Monoaxial accelerometer general purpose, ICP, 100mV/g, weight 5,8 g, range 50 g pk
-
product
High Temperature ICP® Accelerometers
PCB® offers specially designed and tested ICP® accelerometers for conducting vibration and shock measurements under demanding environmental conditions of up to 356 °F (180 °C). These sensors combine proven quartz and ceramic shear sensing technology with specialized, built-in microelectronic signal conditioning circuitry to achieve dependable operation in extreme temperatures and through repetitive temperature cycling. Laser-welded, hermetically sealed, lightweight titanium or stainless steel housings offer further protection from the environment. Prior to shipment, each sensor undergoes a battery of tests to ensure survivability for its intended use. Such tests include temperature soak at elevated temperatures, temperature cycling, and exposure to highly accelerated screening procedures with hydraulically actuated shakers.
-
product
ICP® Shock Accelerometers
Piezoelectric ICP® accelerometers afford a very high signal output (+/- 5 volts full scale) and the ease of two-wire electrical connectivity. Their inherent ruggedness enables them to be severely over ranged without damage. The addition of internal mechanical isolation minimizes the high frequency stress that would otherwise be encountered by their ceramic sensing elements. This mechanical isolation, coupled with an internal 2-pole electrical filter, built into the ICP® circuitry, tailors the overall accelerometer response to assure data quality to frequencies as high as 10 kHz. Depending on the specific model, accelerations in excess of 50 kg can be successfully measured. These modern designs, with their internal elastomeric isolation materials are verified through calibration to remain dynamically linear and are enabling piezoelectric accelerometers to operate in increasingly severe acceleration environments.
-
product
Data Acquisition Card
TPCE
The Elsys TPCE data acquisition (DAQ) cards are high-precision and high-resolution digitizers with sophisticated features such as advanced trigger mode, continuous data acquisition mode, differential inputs, digital input lines (Markers) and ICP coupling for powering piezo sensors.
-
product
Autosamplers
Teledyne has served the AA, ICP, ICP-MS, MC-ICP-MS market for over 30 years with a wide selection of autosamplers that meet virtually all laboratory needs.
-
product
16-Channel Bridge Signal Conditioning Unit
ProDAQ 5716
The ProDAQ 5716 is a 1U high rack-mountable signal conditioning box for standard 19 in. racks. It provides signal conditioning for up to 16 strain gage or ICP sensors. Either one ProDAQ 3416 16-Channel ADC Function Card or up to two ProDAQ 3424 8-Channel 24-bit Sigma-Delta ADC Function Cards can be connected to the unit.
-
product
IEPE Triaxial Accelerometer – 1000 mV/g
HDP356B18
Triaxial accelerometer high sensitivity, ICP, 1V/g, weight 25g, range 5 g pk
-
product
Ultrasonic Nebulizer
U5000AT+
Using an ultrasonic nebulizer in conjunction with an optical ICP system is a simple, cost-effective way to increase sensitivity and lower detection limits.
-
product
Modern Prepolarized Precision Condenser Microphones & Preamplifiers
Modern prepolarized microphones are designed with newer technology than traditional externally polarized microphones. Prepolarized microphones have many advantages over the externally polarized models. They use ICP® power circuitry invented for sensors by PCB®. By applying a polymer coating to the top of the backplate and embedding a charge on it, expensive 200V power supplies can be eliminated and 2-20 mA constant current supplies or signal conditioners can be used as the power source.
-
product
ICP Blast Pressure Pencil Probe
Model: 137B21B
Quartz, free-field, ICP blast pressure pencil probe, 1000 psi, 1 mV/psi, BNC connector
-
product
Compressor-Cooled Incubator
ICP
Our ICP compressor-cooled incubator offers great results whenever a rapid and precise changeover between heating and cooling phases in ramp operation is required. Due to the finely tuned control technology, temperatures exactly reach the setpoint values without the need for energy-intensive bursts of power.
-
product
Transducers
Is a unit which comprises a preamplifier fed by a constant current ICP and a condenser microphone
-
product
USB I/O Module for Sound and Vibration
JSV-4431-USB
4-channel ICP analog voltage input 102.4KS/s maximumsample rate, simultaneous acquisition Analog-to-digital converter:delta-sigma, 24 bits Phase Accuracy < 0.05deg@10KHz Optional Input voltage range: ±10 V,±5V, ±1Vm ±100mV ; Signal conditioning: anti-aliasing filter Digital filter: user-defined low pass, high pass, band pass, band stop Dynamic range: 100 dB ICP current: 0-4 mA, optional 1-channel analog output voltage:±3.5 V; update rate: 96 kS/s Overload indication: software display
-
product
On-line ICP / ICP-MS Sample Preparation System
SDX ʜᴘʟᴅ
The SDXHPLD system combines the proven ASX‑560 autosampler with a novel vortex mixing dilution accessory. The system dilutes in the same way you do by hand: volume-to-volume dilution, using a highly accurate syringe pump. But it also goes an additional step to vortex mix the resulting dilution prior to sample introduction to ICP and ICP-MS.The SDX employs vortex mixing to promote homogenization of a sample to ensure accurate and precise analysis following dilution. The variety of sample matrices submitted for trace element analysis necessitates the need for mixing. This long overdue capability improves data quality by fully homogenizing a dilution mixture rather than performing in-line combination.The SDXHPLD is a straight-forward, fully-integrated solution for automated dilution of aqueous and acid base sample prep for ICP or ICP-MS.