Filter Results By:
Products
Applications
Manufacturers
-
product
Air Quality Analysis
Ambient Gas Monitoring: We offer a variety of analyzers for the ambient monitoring of the criteria pollutant gases, including CO, NOX, SO2, and others such as CH4 and CO2. Source Gas Monitoring (Emissions Monitoring): Experience reliable measurement in your process for emissions compliance every time.Ambient Particulate Monitoring: Experience our monitoring technology and gain the power to do more than just inform.Emissions Calibrators: For continuous monitoring of mercury in exhaust stacks, waste incinerators, and cement kilns, or multi-gas models to control the calibration of gas concentrations.
-
product
CAPS True NO2-NOX-NO Analyzer
Model N500
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
product
Conventional Extractive System
ML660
The Teledyne ML®660 conventional extractive system is designed to extract and condition hot, wet stack gas for a dry basis measurement of any combination of SO2, NOx, CO, CO2, and O2. This system can be configured specifically for 40CFR60, 40CFR63, 40CFR75 compliance, and process control applications.
-
product
Dilution-Extractive System
ML675
The Teledyne ML®675 dilution-extractive system can be used in 40CFR75, 40CFR60, 40CFR63, and process control applications. In this system, sample is prepared for analysis by diluting stack gas with clean, dry instrument air at the probe location. Since no moisture is removed with dilution, measurements for SO2, NOx, CO, THC and CO2 are made on a wet basis.
-
product
Combustion
Our combustion gas analysers are compatible with a wide range of machines, such as engines, industrial boilers, incinerators and industrial furnaces. They can be used to assess various combustion parameters, from efficiency and yield to CO, O, NOx and other gas concentrations in flue and exhaust gases.
-
product
Trace-level, Photolytic, True NO2/NO/NOx Analyzer
Model T200UP
Teledyne Advanced Pollution Instrumentation
The Model T200UP provides trace level measurements of NO and NO2 using our Model T200U NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.
-
product
High Range Chemiluminescence Oxides of Nitrogen Analyzer
Model T200H
The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also available).The T200H may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200H comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Continuous Gas Analyzer In Flue Gas
NSA-308
The NSA-308 can measure five components NOx, SO2, CO, CO2, and O2 in exhaust gas from incineration facilities, etc. Two analyzers are used, a high-performance, high-functionality ratio infrared analyzer and a magnetic wind oximeter.
-
product
Trace-Level Chemiluminescence NO/NO2/NOx Analyzer
Model T200U
Teledyne Advanced Pollution Instrumentation
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.
-
product
Exhaust Gas Measurement Modules
Reliable and precise acquisition of exhaust values: For exhaust gas measurements, i.e. Lambda, O2, NOx, and NH3 in vehicles with petrol, diesel, CNG or LPG engines CSM has expanded its product portfolio with the CAN-based exhaust gas measurement modules from ECM.
-
product
Gas Analyzers
Independent Handheld 5 Gas Analyzer or use with MODIS™ Link, VERDICT® and VERUS® Bluetooth® link. Fully Portable 5 Gas Analyzer, go anywhere, use anywhere 110 V AC and 12 V powered Internal rechargeable battery, up to one hour of use Ideal for road testing and mobile use Measures exhaust emissions for CO, CO2, HC, O2, NOx and AFR/Lambda Provides an instant assessment of an engine vehicle exhaust and catalytic converter MODIS, VERDICT® and VERUS® Link for enhanced real-time viewing Setup required with included software on USB stick Gather all the evidence required for effective and accurate vehicle diagnostics on one screen in real time View, graph, save and recall data Monitor and reduce vehicle emissions, improve driveability and fuel efficiency There are 255 memory locations in the analyzer to track and print data for the same or many different vehicles Compatible with gasoline, CNG, propane and diesel fuel types Annual calibration and sensor replacement performed at Crystal Lake Northern Repiar enter Meets required industry standard
-
product
Residential/Commercial Combustion Analyzer Kit w/ NOx Sensor/Printer
C165+NKIT
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
CO & NOX Analyzer
714
Combustion Efficiency Analyzer. NO & NOX Analyzer. CO Analyzer(calculatesCO2). Differential Thermometer. Differential Digital Manometer
-
product
Chemiluminescence Oxides of Nitrogen Analyzer
Model T200
The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Continuous Gas Analyzer
CT5400
Multi-component continuous gas analyzer combines QCL and TDL technologies in a single rack mount enclosure to measure process gas and monitor emissions from sub ppm to % levels. The CT5400 is ideal for measuring NOx, SO2, CO, CO2, CH 4, NH3, O2, HCl and other combustion gases identified as pollutants, ozone depleting, or responsible for global warming.
-
product
Heated Type NOx Analyzer
MEXA-1170HCLD
The MEXA-1170HCLD is available as an atmospheric (A) and a vacuum (V) model. With nine ranges available from 10 ppm up to 10,000ppm, these instruments are designed to fit most applications in the industry.
-
product
Multi-Stage Injection Analyzer
FJ-8000 series
Common rail method already is commonly known as an injection system of diesel engine now. That system enables multi-stage fuel injection by offering high injection pressure in various driving situation. Adopting the common rail system helps improving fuel consumption, reducing noise and vibration, because the system can make the fuel approximate complete combustion which suppresses PM and NOx generation. FJ-8000 series is the multi-stage injection analyzer that supports more accurate injection by measuring injection quantity, injection rate, injection timing, and injection period by multi-stage injection of common rail system in the environment that is near to an actual vehicle environment.
-
product
Solid-State Chemiluminescence NOx Analyzer
CL3020
CL3020 CLD NOx analyzer utilizes next generation solid state detection technology to measure low and ultra-low NOx in combustion applications.
-
product
High Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200H
Teledyne Advanced Pollution Instrumentation
The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also available).The T200H may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.
-
product
Washwater Monitoring System
EG-100
Washwater Monitoring System for NOx and SOx Scrubber.Monitoring pH/Temperature, Turbidity, and PAH.EG-100 has flow type sensors.
-
product
Multi-Stage Injection Measurement System
Common rail fuel injection system in diesel engines is a fuel injection system which improves output performance and fuel consumption by purifying exhaust gas (soot, NOX) and reducing noise and vibration.The fuel is completely burned by being sprayed in the form of mist which burns easily at high pressure, and furthermore the combustion timing is optimized with electronic control.In this common rail injection system, injection timing by an electric controlling has great effect on the performance of an engine. So measurement of injection amount, injection rate, and injection timing are very important. FJ-8000 series Multi-Stage Injection Analyzer is able to measure those parameters for every 1 cycle by simulating in the environment which is near to an actual vehicle running.
-
product
Mid-Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200M
Teledyne Advanced Pollution Instrumentation
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers.
-
product
On-Board Systems
OBS-ONE series
HORIBA developed the OBS-ONE series on-board emission measurement system in response to new requirements for exhaust emissions measurement from vehicles being driven on public roads (Portable Emissions Measurement Systems - PEMS). This development has been made possible by reducing the dimensions and power consumption of laboratory grade analyzers and ensuring that the system components have excellent vibration resistance. The OBS-ONE series continuously measures not only the concentration of CO, CO2, THC and NOx, but also measures exhaust fl ow rate and A/F ratio to calculate mass emission and fuel economy.
-
product
Portable Exhaust Gas Analyzer
IMR 1440FL
IMR Environmental Equipment, Inc.
The exhaust gas analyzer, IMR 1440FL/COFL, is designed to measure exhaust gases of Forklift Trucks that are powered by a variety of fuels. According to US regulations, the IMR 1440FL/COFL can measure soot and CO for Forklift Trucks. If state regulations require NOx, the IMR 1440FL/COFL can be equipped with a NOx sensor. The IMR 1440COFL is equipped with two CO sensors. One CO sensor operates in the low range and another CO sensor operates in the high range.
-
product
Photolytic True NO2/NO/NOx Analyzer
Model T200P
Teledyne Advanced Pollution Instrumentation
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.
-
product
Continuous Emission Monitoring System
CEMS
CEMS, the “Environmental Eye” for Source Emissions.A Continuous Emission Monitoring System (CEMS) is an integrated system to measure fuel flow, dust, and concentrations of air pollutants such as SO2, NOx, CO, CO2, THC and O2 in accordance with the applicable regulations for the emission source.
-
product
Mid-Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200M
Teledyne Advanced Pollution Instrumentation
The Model N200M uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
product
Mid-Range Chemiluminescence Oxides of Nitrogen Analyzer
Model T200M
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers. The T200M may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
On-board Emissions Measurement System
OBS-ONE GS Unit
OBS-ONE is the latest Portable Emissions Measurement System designed for engine/vehicle certification under real road conditions.It measures concentrations of emissions (CO, CO2, THC, NOx, NO2), particulate matter, air-to-fuel ratio, exhaust flow rate, GPS data, environmental conditions (atmospheric temperature, humidity and pressure) and calculates mass emissions.OBS-ONE features the highly adaptable, intelligent operating platform called “HORIBA ONE PLATFORM” which integrates other ONE series product data and optimizes test cell operation.
-
product
Ambient Air Quality Monitoring System
AQMS
AQMS, the doctor for "Human Health"An Air Quality Monitoring Station (AQMS) is a system that measures metrological parameters such as wind speed, wind direction, rainfall, radiation, temperature, barometric pressure and ambient parameters. The AQMS also integrates a series of ambient analyzers to monitor the concentration of air pollutants (such as SO2, NOx, CO, O3, THC, PM, etc.), continuously. HORIBA also provides mobile monitoring stations that can be used to monitor ambient conditions at multiple sites.