Filter Results By:
Products
Applications
Manufacturers
-
product
Bench Digital Multimeter, Calibrated, 1 kV, 10 A, 3.8 Digit
72-1015 CAL
The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
product
Capacitor for AC Filtering
PECA4 (900V)
Lifasa - International Capacitors, SA
These capacitors are especially suitable for applications where high levels of AC voltage are required. The design of this series has been optimized for the manufacture of high performance AC filters for compensation equipment with high pollution such as UPS or wind turbines
-
product
Clamp Meter
KT-3500
• Non - intrusive AC and DC current measurement• 10mA resolution• Average responding, RMS calibrated• Auto ranging /Auto zeroing• Data Hold • Low battery indicator• Auto Power OffMeasuring Range: 0 - 500A DC or ACAuto ranging : 50A/500AResolution: 10mA in 50A range, 100 mA in 500A rangeBasic Accuracy: ±1.3% rdg ±5 digitsTemperature coefficient: ±0.05% of rdg /°CFrequency range: DC in DC: 40 HZ to 400 HZ in ACOverload capacity: 500 ADielectric strength: 3.7 KV RMS.50 Hz 60s(EN61010-2-032 Cat III, 300V Pollution Degree 2)Operating Temperature: 0°C to +50°CBattery removed: -20°C to +60°COperating Humidity : <80%RHPower supply: 9V alkaline batteryBattery life: 20 hours dependent duty cycle Display.: 5000 countDimensions: 184×71×31mmMax jaw capacity: 21mm ø CableMax jaw opening: 25mm
-
product
Emissions Testing
One of the main aims of environmental protection is to suppress harmful emissions or reduce them as much as possible. Typical examples of emissions include gaseous and particulate pollutants emitted by furnaces, odor emissions and particulate emissions from waste tips. Help protect the climate and ask us to measure the emissions created by your facilities.Our experts will test your facility – from large-scale firing plants to biogas plants, from waste incinerators to crematoria – according to national and international standards. We can also help you reduce noise pollution, measure exhaust gases and harmful emissions, and modernize your facilities.With their extensive experience, our experts can analyze your processes and identify potential improvements. As a measurement body registered throughout Germany and internationally accredited according to ISO 17025 we are authorized to perform the legally required measurements for you.Your facilities need testing? Ask us about our emission testing.
-
product
High Voltage Probe
HVP-40DM
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
product
Hydrogeology
HAPPIE
The H.A.P.P.I.E. program (Hazard of Aquifer Pollution Potential Impact Evaluation) provides a conservative answer to the problem of determining risk levels in emergency conditions, which means that areas where illegal waste disposal sites, overflows and ruptures of impermeable sheeting are present and where water withdrawal should be discontinued can be identified. H.A.P.P.I.E. in fact offers a conservative response to the problem of the determination of the environmental impact in critical conditions that can usually be correlated to the requirements of defining areas in which the supply operations should be interrupted in emergency conditions, therefore in very short times and without the possibility of obtaining an accurate collection of the hydrogeological data.
-
product
Epoxy Resin Silicon Rubber Outdoor Voltage Transformer
JDZW-10RG
Beijing GFUVE Electronics Co.,Ltd.
Outdoor voltage transformer of the type JDZW-10 is single phase and epoxy resin silicon rubber insulated product, it's used for metering electric energy, voltage control and relay protection in 50/60HZ rated voltage less than 12kV electric system. It can be used for medial voltage AIS, or can be used for medial voltage switchgears. They can operate in all kinds of environments (such as wide range temperature (-50~70℃), high altitude, high humidity, high pollution or salt). This model JDZW-10 outdoor voltage transformer is also as voltage source to supply 220V voltage.
-
product
Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.
72-7226 CAL
The 72-7226 CAL from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.
-
product
Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.
72-7226 CAL DU
The 72-7226 CAL DU from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.
-
product
Noise Control And Acoustical Consulting Services
Our acoustical consultants use the latest and most advanced noise prediction and modeling software, precision sound measurement equipment and detailed acoustical analysis that enable us to help our clients achieve their project's noise requirements and goals. Contact us before your noise challenges become noise pollution problems.
-
product
Fixed Clamp-on Flowmeter
D118
Gentos Measurement & Control Co.
The D118 ultrasonic flowmeter is based on Tansit-time technology, which has ultra-high measurement accuracy. D118 uses an external clipped Transducer, which can collect flow data simply by clamping it on the outside of the pipe, and it will never come into contact with the fluid, and will not cause liquid pollution, pressure reduction, leakage, etc.
-
product
2D Video Luminance Meter
LS-ELF
LS-ELF can record 15 frame’s 2D luminance data per second. Also LS-ELF can record the image while driving 60-80km/h speed. It can be used in many fields as Display, Light pollution, Lighting, Lab, etc.
-
product
Stack Gas Analysis System
ENDA-5000 series
Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.
-
product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL
The 72-7770 CAL from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
product
High Voltage Probe
HVP-40M
*DC 40KV CAT II Pollution 2*600MΩ Impedance*25KV ± 2%, 40KV ± 3%*T.C. 200 ppm/oC*Positive Polarity only.*Resolution 1KV*Need not power.*CE, TUV GS, UL, CUL, IEC1010
-
product
Noise Control And Acoustical Consulting Services
Our acoustical consultants use the latest and most advanced noise prediction and modeling software, precision sound measurement equipment and detailed acoustical analysis that enable us to help our clients achieve their project's noise requirements and goals. Contact us before your noise challenges become noise pollution problems.
-
product
RoHS Testing Equipment (EDXRF)
EDX-2
Rapid development of global economy brings serious environmental issues, which is becoming the focus of all around the world. The RoHS directive EU announced on Feb 13th of 2003 became effective on Jul 1st of 2007 for the purchase of restricting the pollution caused by the dispose of electronic and electrical products. Facing this environmental protection requirement, after years of hard work on R&D, Lisun has successfully developed EDX serious EDXRF spectrometer. EDXRF can detect and measure the hazardous substances restricted in RoHS directive quickly, precisely and nondestructively.
-
product
Continuous Particulate Monitor with X-ray Fluorescence
PX-375
There has been a growing concern regarding particulate matter (PM) pollution and its effects on health. For effective preventative measures, the determination of source PM concentration is extremely important. Therefore, indication of PM and elemental concentrations is critical. The PX-375 analyzer employs automatic sampling, continuous on-line PM quantitative and qualitative analysis for rapid air pollution measurements.
-
product
Light Condition Sensors
The MS-321LR Sky Scanner is designed for building automation, design, daylight software modelling and light pollution research.
-
product
Harmonic Trap Inductors
Osborne designs harmonic trap inductors to work in conjunction with capacitors in power systems to prevent specific line-frequency harmonics from flowing back to the power source (point of common connection). This power quality design approach prevents harmonic currents from flowing to the main facility power system and/or to the utility power system. The Osborne system also reduces unnecessary power losses and power-system pollution.
-
product
EMF Detector
ElectroSensor™
This EMF detector is an unparalleled value that offers fast, reliable, and user-friendly measurements of electromagnetic pollution. Since man-made alternating current (AC) is different from naturally occurring EMF, some sources say that even extended exposure of as low as 2 milliGauss may be harmful. Fortunately, once EMF sources are identified with your ElectroSensor you can moderate your distance and exposure.
-
product
Low Concentration Photo-Voltaic (LCPV) & High Concentration Photo-Voltaic (HCPV) Cell Testing
Concentrated PV Cell testingPhoto-biological studies of plants, animals, and cell culturesSemiconductor testingPhoto-toxicity researchMaterial degradation researchAccelerated UV and solar exposure testing of color fastness and material stability for paints, textiles and plasticsAtmospheric photochemical pollution research
-
product
High-Voltage Test Hood
LX-HVE600
The bright test room with a ball-bearing cover is designed for high production quantities. Thanks to the easily exchangeable exchangeable plate, retrofitting for testing different products is also a simple task. Product properties: External dimensions (W * D * H) approx. 640 * 716 * 640mm Usable test space (W * D * H) approx. 450 * 500 * 460mm Contacting Installation space approx. 100mm high under removable plate Dielectric strength min 10kV Application area up to 2000m above sea level Pollution degree 1 without condensation Standard conformity EN50191 / EN61010-1 Schmersal safety switch AZM161 with guard locking Lid is supported by ball bearings for high number of cycles, the bearings can be easily exchanged for servicing Optionally available, Not included in the price: - Red / green signal light - Mobile substructure trolley with 19 "
-
product
Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.
72-2985
The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.
-
product
New Resistivity Inversion Software
EarthImager 3D
AGI is proud to introduce the new EarthImager 3D resistivity and IP inversion software. This software inverts resistivity and IP data acquired with electrodes arranged in boreholes and/or on the surface and presents a 3D volume of inverted resistivity data with advanced volume rendering technique. The final resistivity or IP image-volume can be rotated in any orientation, zoomed in and out, and translated to anywhere inside the image window in order to see the volume of interest in detail. Colors representing areas of less interest can be made transparent so that the shape of a pollution plume, for example, can be visible. With EarthImager, 3D resistivity inversion can be as easy as two steps: Read Data and Start Inversion with only a few mouse clicks.
-
product
Gas Analyzers
FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
-
product
Environmental Monitoring Systems
Eurotech environmental monitoring systems are designed to provide a scalable, efficient and compact solution that integrates multiple sensors in a single, easy to deploy unit. These compact, easy to install environment monitor systems collect and analyze air quality parameters, electromagnetic fields, ionizing radiation levels and sound pollution.
-
product
Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.
72-7226 CAL D
The 72-7226 CAL D from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.
-
product
Sound Level Meters
Sound level meters measure sound pressure level and are commonly used in noise pollution studies for the quantification of almost any noise, but especially for industrial, environmental and aircraft noise.