Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Battery Simulator Module, 2-Channel, Simplified Current Sink, 750 V Isolation
41-752A-903
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
Power Bead Inductors
Power bead inductors are typically used in high current multi-phase voltage regulators that power processors, memory modules and high current ASICs and FPGA in a wide range of applications including servers, graphics cards, storage and data centers. The construction consists of a ferrite core assembled over a 1T or 2T winding and which allows for extremely low DCR, high peak current and low AC losses. Pulse has single phase, integrated phases and coupled inductor versions. Our high volume manufacturing enables us to produce components that are cost-effective while maintain exceptional quality and reliability.
-
product
High Current SMU Family 500 A
AXC755x
Generate extremely short, fully regulated current pulses from 300 µs up to 500 A. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.
-
product
Lightning Surge Generator
SKS-0506IA
Shanghai Sanki Electronic Industries Co., Ltd.
The lightning surge generator SKS-0506IA fully complies with the new standards of IEC61000-4-5, EN61000-4-5 and GB/T17626.5; it provides pulse test voltages up to 6kV; both AC and DC samples can be tested. The rated voltage of the equipment under test can reach 380V, and the rated current can reach 32A; 7-inch color LCD touch screen, friendly human-computer interaction interface, higher intelligence and more user-friendly operation; the software is built with the level specified by the IEC standard Mode, can be called directly.
-
product
Pulsed IV-Curve Solutions
Pulsed IV-Curve Test and Analysis System is our new development for 2015. It is an advanced and compact pulsed IV-curve characterization system designed to simulate pulsed ESD events such as TLP, vf-TLP, HMM, HBM, EFT, and LV-Surge. It will monitor the transient voltage and current waveform during the pulse in ps or ns segment, and test the pre- and post-pulse status (leakage current, breakdown voltage, biasing current, static IV curve, etc) of the device under test (DUT), such as protection devices, semiconductors, circuit modules, touch panel sensor, etc.
-
product
Power Sources
MS-Series
The MS-Series Power Sources are high performance, high efficiency, AC to AC converters. Rugged powerful output provides up to 350 amps of pulse current for driving non-linear loads.
-
product
Magnetizer
412B
The Model 412B magnetizer provides many of the features of the Oersted Technology 300-series magnetizers in a small benchtop cabinet. This unit is designed for magnetizing parts which require lower energy levels due to their size or the magnetic material used. Like the 300-series magnetizers, the 412B is an ECS magnetizer, which allows the user to electronically vary the capacitance of the unit. The capacitor banks are internally discharged through a safety circuit in case of power failure or accidental power-down. When the 412B is connected to a properly equipped fixture, the front-panels can be inhibited through an overtemperature interlock circuit, preventing the magnetizer from being operated once the fixture begins to overheat. An external output is also provided for monitoring the magnetizing current pulse with an oscilliscope.
-
product
High Current SMU 1600 A
AXC7585
Generate extremely short, fully regulated current pulses from 300 µs up to 1600 A. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.
-
product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
Compact Automatic Voltage Regulating Relays
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
product
Magnetizer
U-Serie
MAGNET-PHYSIK Dr. Steingroever GmbH
The pulse magnetizers of the U series are suitable for a wide range of applications in the laboratory and in production. With low energies, they are ideally suited for sensor systems made of ferrite material, which can be magnetized with short cycle times at currents of up to 20 kA. In the energy classes 1,400 Ws and 2,800 Ws, rotors with NdFeB magnets up to a diameter of approx. 60mm are typical applications. With this device, you can magnetize with pulse currents of up to 60 kA.
-
product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
Surge Generators
Hybrid
Surge pulses occur due to direct or indirect lightning strikes in a circuit or by switching transients caused by switching inductive loads or short circuits. This leads to currents or electromagnetic fields causing high voltage or current transients. Surge voltages and currents can reach several thousands of volts and thousands of amperes. Our following Surge generators simulate these disturbances for all the necessary level in accordance with IEC / EN 61000-4-5 and IEC / EN 60060.
-
product
Documenting Multifunction Calibrator
DMC-1400
The DMC-1400 Calibrator fully documents any calibration easily while performing the normal job. No special software is required! It features the ability to test for pass/fail criteria, measure and simulate thermocouples, RTDs, current, voltage, and frequency, and source pulse trains. PLCs, full fuseless protection, and a serial communications port for full control with ASCII commands.
-
product
Magnetizer
345B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
Pulse Magnetic Field Generator
SKS-0902
Shanghai Sanki Electronic Industries Co., Ltd.
The technical parameters of the pulsed magnetic field generator SKS-0902 fully comply with the new standards of IEC61000-4-9 and GB/T17626.9; the pulse current output of up to 2000A can meet the needs of different user groups; it adopts a self-developed CNC high-voltage power supply, High precision, high stability, long service life; using self-developed high-voltage electronic switch as the main switch, high stability, smooth output waveform; achieving 0°~359° synchronous phase triggering.
-
product
SIRIO
4AAX4A
Sirio is a low-cost multi-function meter in a 4 DIN module, ideal for measurement and display of the most important electrical parameters.Sirio can be installed in single phase and three-phase unbalanced systems in a triangle or in a star layout with sturdy 4 mm2 terminals for measuring the current and voltage.It monts an 8 digits LCD display. It displays 7 major measures (True RMS) and more than 40 RMS are available on the integrated RS485 serial port.Siri0 include two relay outputs, user-configurable for alarms, pulse or remote control.All parameters are configurable from instrument keyboard already installed.
-
product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-01
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
product
High Voltage 50 Ω Pulse Generator
TLP-8010C
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
product
PXIe-4135, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit
783762-01
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4135 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
product
30 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP031
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
product
Split type Pulse Current Sensor
CTF-05
MULTI MEASURING INSTRUMENTS Co., Ltd.
High accurate AC pulse current sensor for power demand meter.
-
product
High Voltage SMU 2500 V
AXV7607
Generate extremely short, fully regulated voltage pulses of up to 2500 V. Measure leakage currents up to the pA range.
-
product
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse
T3CP30-100
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse.
-
product
Split type Pulse Current Sensor
PCT-06
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Through hole type pulse current sensor.*Pulse current sensor for power demand meter.
-
product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)
-
product
Premium Data Loggers with 1-4 Channels
Premium Data Loggers for temperature, humidity, co2, atm. Pressure, voltage, current, pulse and 2-state inputs.
-
product
AMIDA VCSEL Tester
AMIDA VCSEL tester can be divided into three parts: LIV measurement system, Near Field measurement system and Far Field measurement system. To achieve the above three measurements, in addition to the necessary optical components and optical instruments, the core technology is to provide fast and stable current pulses to drive the VCSEL laser diode to emit light, and then to test various optical and electrical properties
-
product
Diode Driver & Laser System Controllers
The laser controllers provide a simple method of controlling Lumina and other popular laser diode drivers or full laser systems. They include the ability to easily control current levels, pulse modes, and interlock controls as well as monitor voltage and current levels as well as q-switch triggering, external triggering, sync output, and additional I/O signals.
-
product
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030B
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
product
Flow Sensors
Rugged and precise – flow measurement technology from SICKSICK provides innovative sensor solutions for flow measurement technology which combine flexible measuring methods and rugged equipment design with cost-efficient connection concepts to integrate higher-level systems. Whether you need to detect the current flow rate value using analog values or find the quantity using pulse detection – SICKs flow sensors are always reliable and safe and can work with a wide range of media under difficult process and ambient conditions.