Filter Results By:
Products
Applications
Manufacturers
Spectral Response
sensitivity of sensor to a specific wavelength over a spectral band.
See Also: IPCE
-
product
Combined Illumincance and Irradiance Probe
LP471P-A
Combined probe for measuring ILLUMINANCE (lux), with standard photopic response, and IRRADIANCE (μW/cm²) in the UVA spectral range (315…400 nm, with peak at 360 nm).
-
product
Photometric Probes for Illuminance
LPPHOT03… Series
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
product
SiTek UV PSD
The UV PSD is a detector optimized for use in the UV wavelength region 200-400 nm, although its spectral response reaches up to 1100 nm. The sensitivity in the UV region (200-400 nm) is extremely high. The UV-PSD has the same outstanding specifications as the standard SiTek PSD.
-
product
Image Sensor/Fingerprint-on-Display Testing
Enli Tech provides the most advanced optical and non-destructive inspection technology, which can de-convolute the digital images back to the analog properties, such as quantum efficiency, spectral response, system gain K, Dynamic Range (DR), PRNU, DRNU, Linearity Error LE, and Chief-Ray-Angle (CRA). The testing solution can be applied to CCD and CMOS image sensors in aerospace, defense, and scientific camera field. Image sensor packages that can be tested by Enli Tech’s systems include bare wafers, dies, chips, or camera modules. Our image sensor testers can help users reduce the sensor-modules or camera-modules development time and RD budget.
-
product
Extreme Low Power Detector Laser Power Meters
11XLP12
11XLP12 extreme low power detector is best suitable for low power im both the µW and mW regimes with very low thermal drift. Featuring broadband flat spectral response, minimal thermal drift and a noise equivalent power as low as 1 µW the 11XLP12 is ideally suited for measuring any pulsed or CW low power laser.
-
product
Digital Lux Meter
PM-3
Is a compact, lightweight & easy to use Illuminance meter. The sensor is a highly stable silicon photo diode having a wide measuring range. Its spectral response is closely matched with the CIE relative photopic luminosity curve by multi-element glass filters. The sensor is also cosine corrected for true response at variable incidence angles.
-
product
Energy Probes
RjP-400 Series
The RkP-400 Series probes consist of a compact detector assembly, or head, and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1" (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
product
Radiometer Spectral sensitivities precisely adapted to the measurement task
UVS-B-T
Compared to the spectral response of the UVS-E, the UVS-B-T has a sharper cut-off at the transition from UV-B to UV-A. This feature reduces the UV-A contribution to the radiometer output and permits the highest possible correlation to atmospheric UV-B irradiance.
-
product
Hybrid Picosecond Photon Detectors
HPPD Series
technology.The HPPD is our latest development in TCSPC detector technology that combines the benefits of conventional PMT design (wide spectral response and large active area)with the advantages of solid state APD technology (good detection efficiency, negligible after-pulsing and exceptional temporal resolution). Hybrid detectors are becoming thefirst choice for FLIM and short lifetime determination.
-
product
Product Range
Solus
Introducing Protea's new range of laser gas analysers - Solus. The Solus platform represents an extension of Protea's spectroscopic gas analysis equipment into laser based technology, allowing for highly selective, quick response and low range measurements of 1 or 2 gases in a cost-effective, re-configurable package. Solus utilises the latest in Tunable Laser Diode Absorption Spectroscopy (TDLAS), together with the best in micromachining technology, to deliver a precisely controlled narrow wavelength that can be tuned over a small range. The narrow linewidth allows for selection of precise spectral absorbance in the NIR region, free from cross-interferences of other absorbing gases. For some tuning ranges, a number of gases can be measured by tuning a single laser diode e.g. NH3 and H2O.
-
product
USB Smart Detector
OL 731
The OL 731 USB Smart Detector is a low-cost, hand-held radiometer/photometer that can be tailored to the spectral response of the user's specific application requirements with the use of a range of sensors and filters. Several units can be multiplexed on to one USB, and it can be programmed to read in any user-specified radiometric or photometric unit. The OL 731 is suitable for a variety of critical applications.
-
product
Radiometer Spectral sensitivities precisely adapted to the human skin
UVS-E-T
The UVS-E-T has a spectral response that is adapted to the erythemal (sunburn) action spectrum of the human skin (CIE 1987 weighting). Hence, this radiometer collects information of medical and public concern: UV Index, UV Erythemal dose and dose rate.
-
product
Chips and Diodes
NC100/200/300/400 Series
Noisecom's noise diodes are the fundamental building blocks for analog noise systems. They are sorted for performance characteristics that enhance their broadband noise output and flat spectral response. All Noisecom noise diodes can deliver symmetrical white Gaussian noise and flat output power versus frequency
-
product
Spectral Response (Spectral Sensitivity) Measurement
It is used to measure the spectral response (spectral sensitivity) of photoelectric conversion devices (photodetectors / sensors) such as silicon photodiodes and CCD · CMOS image sensors . Measurement in the broadband wavelength region can be performed with low stray light.
-
product
Handheld Raman Analyzer
TacticID®-1064
The TacticID®-1064 is a field-ready handheld spectral analysis instrument designed for non-contact forensic analysis by safety personnel and first responders, including law enforcement personnel, bomb squads, customs and border patrol, hazmat technicians, and more. The TacticID®-1064 utilizes proven Raman spectroscopy, allowing users to get real-time actionable identification of unknown chemicals, explosives, narcotics, pharmaceutical drugs and many other substances while reducing operational uncertainty and response time. The TacticID®-1064 includes a comprehensive library of over 10,000 substances. In addition, users have flexibility to create their own libraries. By utilizing the 1064nm wavelength, the TacticID®-1064 avoids fluorescence, allowing users to get results in less than 1 minute even when working with tough street samples.
-
product
Complete Testing Solutions
System includes a lamp and monochromator for a tunable light source, which is coupled to a high sensitivity source meter with measurement software. This user-friendly system is the most powerful Spectral Response system currently on the market, but its true power is the ease of upgrading from the base PTS-1 to the more powerful PTS-2-QE (Quantum Efficiency) or PTS-3-CPM (Constant Photocurrent Method). Designed for researchers who have limited budgets but want to start work immediately, this allows the ability to do baseline studies until additional funding for the full QE or CPM system becomes available.
-
product
Power Probes
RkT Thermopile Series
The RkT Series thermopile power probes are ideal for measuring Nd:YAG, CO2, and other mid-power lasers. The probes are designed to withstand average power densities up to 20kW/cm2 (15MW/cm2 peak pulse power density). The flat UV to far-IR spectral response allows the probes to measure broadband sources as well. Measure the power of cw sources or the average power of sources pulsed at 5Hz or greater.
-
product
Pyranometer Negligible thermal gradient zero-offset
CMP 22
CMP 22 has all the features of CMP 21 but uses very high quality quartz domes for a wider spectral range, improved directional response, and reduced thermal offsets. Because of the high optical quality of these domes the directional error is reduced below 5 W/m. Kipp & Zonen is confident that CMP 22 is the best Pyranometer currently available.
-
product
EQE/Photon-Electron Conversion Testing
Enlitech offers different solutions for incident photon-electron conversion testing systems. The available systems include IPCE, PV External quantum efficiency (PV-EQE), Internal Quantum Efficiency, Spectral Response (SR), Highly-sensitive EL-EQE. There are over 1,000 SCI papers cited Enlitech‘s systems to provide reliable experimental data for significant scientific publication. The Highest PV-EQE sensitivity and EL-EQE both reach 10-5 % (7 orders). They can be utilized to PV conversion efficiency, HJT/ PERC/TOP-CON current-loss analysis, Organic PV charge-transfer-state and Perovskite PV trap state measuring, and Organic PV and Perovskite PV Voc loss analysis.
-
product
Spectral Response SystemsQuantum Efficiency SystemsIPCE Measurement Systems
QE system provides electronics and software designed for fully automated measurement of external quantum efficiency of solar cells. All systems include probes and a fixed plate sample stage for samples up to 150 mm x 150 mm. The main system components include: custom designed software, measurement electronics, and computer system (Windows 8 operating system). The measurement involves focusing monochromatic light to a spot on the device under test, then accurately measuring the photon flux and current from the test cell. The system utilizes a dual beam configuration with lock-in detection, providing an absolute accuracy of ±3%. The QE system uses a grating monochrometer with silicon/InGaAs/Ge detectors. The system includes automatic order sorting filters and two light sources for monochromatic illumination (a Xenon- arc lamp and a halogen lamp). A single lock-in amplifier is used to measure both the reference detector and test device. The main system comes with all the hardware needed to measure quantum efficiency, a fixed plate sample stage and probes.
-
product
Pyrgeometer Low Temperature dependence of sensitivity
CGR 4
CGR 4 pyrgeometer is an instrument for the highest quality scientific measurements. The specially designed meniscus dome provides a 180 field of view with negligible directional response error. A hard-carbon coating on the outside of the dome smoothes the spectral response and provides extra protection to the silicon surface.
-
product
Illuminance Probe
LP471PHOT
Photometric probe for measuring the ILLUMINANCE, spectral response according to the photopic curve, class B according to CIE N° 69, cosine correction diffuser.
-
product
Detector Testing
CI Systems' Optical Test benches are especially built to test many types of detector arrays used as the sensors of a camera, from visible to far infrared ranges. With CI Systems' expert know-how, these test benches can be tailored to a customer's design requirements. MTF, spectral response, crosstalk, NETD and sensitivity are some of the basic parameters that can be tested with CI's Optical Test benches during the design, manufacturing and integration of detector arrays.
-
product
Luminance Probe
LP471LUM2
Photometric probe for measuring the LUMINANCE, spectral response according to the photopic curve, angular field 2°.
-
product
Ultra-Micro Spectrometers
UltraMicro
spectro-module is constructed by a new invented technology and can provide high optical resolution and fast spectral response. The optical engine is very simple and optimized for the spectrometer. The optical bench is very rigid and stable for measurement system. The compact size is very flexible for system integration.
-
product
Computerized Knife-Edge Tomography (CKET)
Many new generation lasers, having a spectrum which is out of the sensitivity response of typical camera detectors require different technologies to be ex-amined. Tomographic knife-edge technology offers a feasible solution. Multiple knife-edges scanning from different directions provide beam profiles depen-dent on scanning angle. By reconstruction techniques used in tomography, an image-like profile can be reconstructed and analyzed. Various detectors are used to provide a wide spectral range measurement capability
-
product
Solar Energy, PV Monitoring
Apogee silicon-cell pyranometers feature a monocrystalline silicon-cell detector that has the same spectral response as a PV module. The sensors quantify shortwave radiation being harnessed as electricity.
-
product
UV TOCONs
SiC based UV sensor with integrated amplifier and 0 – 5 V voltage output. Measures intensities from 1.8pW/cm² up to 18W/cm². Spectral response for broadband UV or filtered for UVA, UVB, UVC or UV-Index. Also available for blue light (GaP chip) or visible light (Si chip) measurement. Available in TO5 housings or as miniature sensor probes (stainless steel or plastic). Special TOCONs for hydrogen flame sensing (TOCON_F) and for fire detection (TOCON_N) available. Also available for operating temperatures up to 120°C (standard is 85°C). Please learn more about the sglux TOCONs here: TOCON selection guide and here: TOCON User Guide.
-
product
UV Photodiodes
Active area from 0.06 mm² to 36 mm² and quadrant photodiodes for position detections. Spectral response for broadband UV or filtered for UVA, UVB, UVC or UV-Index. Various entrance optics and housings options available (TO or SMD). Our own SiC photodiode chip production since 2009 also available with VUV sensitivity. PTB (German equivalent of NIST or NPL) measured high radiation hardness. 350°C high temperature stable photodiodes available. Photodiode application guide.
-
product
Dynamic Gas Analyser
ExQ
The Hiden ExQ quantitative gas analyser is a new multi-featured and compact mass spectrometer system providing continuous on-line analysis of dynamic gas streams at pressures from sub-atmospheric up to 30 bar, the fully integrated system now being configurable both for benchtop and for rack-mounting operation. Connection to the process is via a flexible heated inert capillary line with a sample consumption rate less than 10 mL/minute and a response time of less than 300 milliseconds at pressures near atmosphere. The comprehensive range of process interface options enables adaptation of the system to accommodate analysis of up to 16 individual process streams, and adaptors are available for direct connection of the system to most standard TGA/TA instruments. External process data, sample temperature or mass for example, can be imported for combined integration and presentation with the mass spectral data.