Filter Results By:
Products
Applications
Manufacturers
Total Harmonic Distortion
Is a measure of a signal's sum power of all harmonic components to the power of the fundamental frequency.
See Also: Distortion, Intermodulation Distortion, THD
- Applied Rigaku Technologies, Inc
product
Total Sulfur Process Analyzer
NEX XT
Applied Rigaku Technologies, Inc
Featuring third-generation X-ray transmission technology, the NEX XT represents the next evolution of process gauge for sulfur measurement (0.02% to 6% S) of crude, bunker fuel, fuel oils, and other highly viscous hydrocarbons, including residuums.The Rigaku NEX XT system is faster, more sensitive and far more compact than competitive systems, and provides continuous, reliable detection of sulfur at pressures up to 1480 psig. Rigaku NEX XT can operate as a stand-alone analyzer or provide real-time closed-loop control when tied into a blending or plant-wide automation system. Among its other key features are a simplified user interface, reduced standards requirement, automatic density compensation, password protection, and standard platform for communicating sulfur and density to a plant-wide DCS. Due to its unique design and robust construction, sample conditioning and recovery systems are typically not required.
-
product
AC Power Source
LSP-500VAR
• AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU • Protection for over hot, thundering voltage and current • Total voltage distortion: ≤0.3%; Voltage stability: ≤0.05%/30min • Load adjust rate: ≤0.05%; Frequency stability: ≤0.01%/30min • Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz • It is pure sine wave AC power source with low harmonic and high accuracy • Input Power: 220V and 50/60Hz (110V can be option) • Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.
-
product
Power Quality Analyzer
Power quality analyzer is a product carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, man-machine operation and concise and comprehensive test instrument. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
-
product
Digital Power Meter (Harmonic Analyzer Model)
LS2010
• Measure Vrms, lrms, W, PF, Hz; • Harmonic distortion analysis for voltage & current, display total harmonic and 0-50 times; • Component harmonic, selectable for absolutely or relatively harmonic display; • Voltage range: 10.0-600.0V, Current range: 0.010-20.00A, Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit); • Simultaneously display Vrms, lrms, W, PF value on 4 windows, suitable for production line; • Can test every kinds of curve; Print both data & curve; • Communication port for PC, run under WinXP or Win7.
-
product
G.fast Transformers
Our line of G.fast transformers are the preferred choice of engineers seeking the most reliable, functional isolation transformers for G.fast transmission. These compact transformers deliver excellent longitudinal balance and total harmonic distortion performance.
-
product
AC Power Source, Frequency Converter
BL1350 Series
Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less than 0.5%, high efficiency, plus excellent line and load regulation.
-
product
Power Analyzers & Wattmeters
Measurements International Ltd.
Direct Replacement for 2010A Wattmeter in the AccuLoss® Loss Measurement Systems, Basic Power Accuracy < 0.005 %, 10 Current Ranges, 2 Voltage Ranges, Line-and-Line and Line-to-Ground Voltage Measurements, Full Power Factor Range, Complete Waveform Analysis, Total Harmonic Distortion Analysis, Phasor Analytical Representation.
-
product
Operational Amplifiers
Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Digital Power Meter (High Accuracy Model)
LS2050
LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.
-
product
Power Quality Meter
Qualstik
The Qualstik Power Quality Meter has been developed specifically for measurement of four important items of power quality in the electric utility industry. These are Current, True Power Factor, Total Harmonic Distortion and the Direction of Current Flow.
-
product
mAEStro Audio Analog to Digital Converter
The mAEStro AADC-100 accepts balanced stereo analog audio inputs and converts them into a single digital bit stream in compliance with the AES/EBU (AES3) and S/PDIF digital audio standards. It generates 24-bit values and uses 128 times over-sampling for extremely accurate and linear analog to digital conversion, as well as offering a high dynamic range with exceptionally low total harmonic distortion and noise.
-
product
AC / DC Digital Power Analyzer
4016(800Vp,20Arms/200Ap)
To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.
-
product
Ultra-Low Distortion Function Generator
DS360
Stanford Research Systems, Inc.
The performance of a low distortion analog source and the precision of direct digital synthesis (DDS) is combined in the DS360. With less than 0.001 % total harmonic distortion (THD), 25 ppm frequency accuracy, and a broad range of features including sweeps and bursts, the DS360 is the ideal source for audio frequency applications.
-
product
Clamp-on Meter
SDC96
True RMS for AC measurement. Total harmonic distortion [50Hz/60Hz] for AC. Measurement. Peak measurements. Measures up to 700 AC/DC amps
-
product
LCD Power Meters
Accuracy ±0.1% F.S. Measuring and display ACV/ACA/Watt/Var/VA/Power Factor/Frequency/KWH/DM(Demand) Input measurement network can be selectives(1P2W/1P3W/3P3W/3P4W) CT rate/PT rate can be modified(1 to 9999) Measuring ACV/ACA total harmonic distortion(THD),up to 35th harmonic(optional) Two alarm control function (optional) Two pulse output function (optional) Digit RS-485 interface function (Optional)
-
product
AC-DC Power Supply Solutions
Advanced Conversion Technology, Inc
From single to three phase inputs, 60 Hz or 400 Hz, ACT can provide you with a design to meet your demanding applications. ACT can also provide designs that incorporate an active PFC front end, single and three phase, which provides less than 3% total current harmonic distortion.
-
product
Distortion Analyzer
SINAD
SINAD utilizes the latest in Digital Signal Processing (DSP) technology to accurately measure several key performance characteristics of radio receivers by analyzing the spectral content of a received audio signal.
-
product
Total Stations
GeoMax total stations offer you an excellent price-to-performance ratio without compromising quality.
-
product
Total Stations
Zipp02 Series
With vertical compensation and 2” accuracy the Zipp02 provides you with the precision required for your most demanding jobs at an affordable price without adding complexity. The Zipp02 is the tool of your choice when it comes to checking angles, alignments, grade work and short range leveling.
-
product
Distortion Test Sets
DTS-C
Matrix Test Equipment Incorporated
The Model DTS Distortion Test Sets combine Matrix products with those of other manufacturers. When properly equipped, a Model DTS can measure virtually any parameter important to the CATV industry. Controlled completely through the (GPIB) IEEE-488 bus interface, a Model DTS allows rapid, repetitive, and objective readings in a production-type environment.
-
product
Solar Total Pyranometers
SK08 & SK08-E
The Middleton SK08 is an affordable pyranometer for the measurement of global solar irradiance on a plane surface. It meets the international accepted specifications for a good quality pyranometer. The SK08 incorporates a passive thermoelectric sensor. The SK08-E version has an inbuilt signal amplifier.
-
product
Laboratory Analyzer for Total Sulfur and Total Nitrogen for Gases and Liquids
XT-2000
XT-2000 is the most innovative laboratory analyzer on the market for reliable total sulfur and total nitrogen measurement on the market today. The XT-2000 laboratory analyzers are designed and built for precise, accurate and reliable analysis with the flexibility that allows the measurement of a wide range of samples with a single instrument.
-
product
Harmonic Generators
Our harmonic Generators include Doubler, Tripler, and Quadrupler for doubling, tripling, and quadrupling laser frequency in the wavelength range 680-1300nm. The second harmonic, third harmonic, and fourth harmonic generation up-convert the laser frequency to a wavelength range 190-650nm. These harmonic generators greatly expanded the application of wavelength range for femtosecond and picosecond lasers available for both amplifiers and oscillators.
-
product
Total Stations
X-Pole
Work simultaneously with Total Stations and GNSS by combining the advantages of both systems. GeoMax X-POLE significantly improves the performance and flexibility on the jobsite.
-
product
Harmonics And Flicker Measuring System
ProfLine Series
The Teseq ProfLine system is a complete and cost effective Harmonics and Flicker measurement test system which compiles to the latest IEC/EN standards, including IEC 61000-3-2 and IEC 61000-3-3. The programmable power generation capability of up to 45 kVA (90 kVA and 145 kVA sources comprise multiple 45 kVA units) provides more than ample power to cater for a wide range of Equipment Under Test (EUT).
-
product
Precision Multi-Channel Harmonic Power Analyzer
PA900
Vitrek PA900 Precision Harmonic Power Analyzer, a refreshingly easy-to-use high performance power analyzer that won’t break your budget. The PA900 delivers multi-channel, high-accuracy, wideband performance – to tackle the toughest energy measurement applications. Trust Vitrek to deliver world class power measurement capability at a price that is surprisingly affordable.
-
product
Total Organic Carbon Analyzer
TOC-L Series
The TOC-L series of TOC analyzers adopts the 680°C combustion catalytic oxidation method, which was developed by Shimadzu and is now used worldwide. While providing an ultra wide range of 4 μg/L to 30,000 mg/L, these analyzers boast a detection limit of 4 μg/L through coordination with NDIR. This is the highest level of detection sensitivity available with the combustion catalytic oxidation method. In addition, the combustion catalytic oxidation method makes it possible to efficiently oxidize not only easily-decomposed, low-molecular-weight organic compounds, but also hard-to-decompose insoluble and macromolecular organic compounds.
-
product
Automated Total Nitrosamine Analyser
Ellutia Chromatography Solutions
Nitrosamines are carcinogenic compounds that can be found and formed in many products. This has been a particular issue in the pharmaceutical industry recently. Traditional approaches to the analysis, such as by mass spec, have been challenging due to the low detection levels required, the possibility of false positives, or even missing. This system takes a unique approach of using the combination of a chemical reaction targeting nitrosamine compounds, then detection by a detector with very high selectivity and sensitivity for nitro/nitroso compounds. Rather than speciating the various nitrosamines present, the system gives a single quantitative result down to 1 ppb for the total nitrosamine content. This means both volatile and non-volatile nitrosamines are measured at the same time. This process is automated to allow a high sample throughput. This makes it ideal for screening a large number of samples rapidly.
-
product
Total Halogen and Sulfur Analyzer
XPLORER-TX/TS*
The XPLORER-TX/TS is a microcoulometric combustion analyzer for the analysis of total halogens and total sulfur. The small footprint allows it to blend into every laboratory environment, whether it is in R & D, refinery, chemical, or petroleum applications. This next generation analyzer surpasses all others in its class in performance. It is robust, precise and ideal for harsh testing environments.