Filter Results By:
Products
Applications
Manufacturers
-
product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
product
3 Phase Voltage Transducer
Converts a three phase, 600 VAC, 50/60 Hz power system to three proportional 0 to 5 volt DC outputs.
-
product
AC Voltage and Frequency Transducers
NMTU/F
The NMTU/F device is an AC voltage and frequency transducer with two independent analogous outputs. The A output measures AC voltage, the B output measures the frequency of input voltage. That´s why one single NMTU/F transducer is able to replace two customary transducers, thus making it possible to achieve significant savings in installation space.
-
product
AC and DC Current or Voltage Transducers
VT7 AND VT8 Series
The Model VT7 Series dc voltage transducer produces an output which is directly proportional to the input from dc to 10kHz. It functions as a millivolt dc shunt or a high voltage isolator to 1000V
-
product
Analog Transducers
CR Magnetics Analog Transducers provide the easy to use tools to monitor any electrical power system, power supply, or electrical load. From simple DC to DC voltage transducers, to complex real and imaginary power transducers, CR Magnetics has the exact input, output, and sensing technology to meet the needs of any electrical power sensing application.
-
product
Electrical Power Transducers
Manufactured for utilities since 1969, TransData Power Transducers are used for measuring AC and DC power variables in Substation, Generation, Load Control and Industrial applications where ±1ma or 4-20mA analog signal are required by the SCADA/Energy Management System. Models are available for measuring Current, AC Voltage, DC Battery Voltage, Watts, VARs, Frequency and more.
-
product
Displacement Transducers - DC Operation
Columbia Research Laboratories
The Columbia DDCP Series Transducers are completely self-contained displacement measurement systems that operate from a low voltage DC power supply or battery. They permit highly accurate readout and recording of an output signal directly without auxiliary signal conditioning electronics.
-
product
In-cylinder Linear Position Transducers
Our In-cylinder Linear Position Transducers are well suited to hydraulic and pneumatic applications. Many of our In-cylinder Linear Position Transducer have features including; touchless magnetostrictive measuring process, unlimited mechanical life, absolute output voltage or current and many more. See our range of products below, click on the links for more information and data sheets.
-
product
ChenYang Voltage Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
DC voltage sensor/transducer works according to Linear PhotoelectricalIsolation and is designed for applications to measurement and monitoring of DC voltage. Theoutput signal (DC voltage or current) of this transducer is proportional to the input DC voltage.They are suitable for measurements and long time monitoring of DC voltages and can applied topower supply management, DC motor drivers, battery chargers and systems etc.
-
product
Process Voltage & Current Data Loggers
Monitor and log virtually any process voltage or current output from your transducers.
-
product
Phase Angle and Power Factor Transducer of Single-phase AC Electric Power
NMTFi
The NMTFi device is a phase angle and power factor transducer operated in single-phase power network and featuring two independent analogous outputs. The A output measures the phase angle between voltage and current, the B output measures the power factor. In such a was one single NMFTi transducer is able to replace two customary transducers thus making it possible to achieve significant savings in installation space.
-
product
GAOTek Portable H/L Voltage Clamp Current Leaker
GT00YA00ZX
The GAOTek Portable H/L Voltage Clamp Current Leaker measures high voltage current with a 12.5 in (32 cm) insulating rod, adopting the latest CT technology and integrating mask digital technology. This instrument provides high precision, reliability, and stability with its integrated design between transducer clamp and domain. This leaker can be used to measure any wire with or without the insulation layer where the voltage is below 10 kV. The insulating rod is portable, moisture resistant, heat resistant, shock resistant, and insulating. It provides additional functionalities such as online current testing, peak and data holding, data storage, detection of high and low current in primary and secondary circuits separately, and provision of suitable calculations to conclude change in high and low pressure.
-
product
NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783311-01
±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.
-
product
16-Channel VME AC Power Analysis Module
V180
The V180 is a single-width VME module that allows accurate and comprehensive measurement of AC power circuits. The V180 acquires powerline current and voltage inputs using approved current transformers and model C750 remote potential transducers.
-
product
3-28V Cordless Circuit Tester
1948
Peaceful Thriving Enterprise Co Ltd
*With CE & UKCA Approvals.*Detect voltage from 3V to 28V.*No ground wire or clip required.*Replaceable long-life alkaline batteries included.(Power supply: SUM5 1.5V X 2 pc)*Safe with ECMs, sensors, transducers and air bags.
-
product
4-20mA Bridge AmplifierR
90416
This miniature, on-board, transducer amplifier is capable of supplying excitation voltage and amplifying millivolt signals from strain gage based transducers.
-
product
48-Channel High Performance Strain Gauge Measurement Instrument
EX1629
48-Channel High Performance Strain Gauge Measurement InstrumentSupports quarter-bridge (120, 350Ω or user defined), half-bridge or full-bridge24-bit ADCs, sampling rates up to 25 kSa/sBuilt in programmable differential excitation -8V to 8VBuilt in selectable bridge completionConfigure signal conditioning excitation and bridge completion on a per channel basisSimple, low-cost wiring using RJ-45 telecom connectorsSupports TEDS for easy transducer detection and setupRJ-45 input connector reduces setup cost and timeBuilt in self-calibration and shunt calibrationSupports voltage, ratiometric and linear measurements other than strain measurements.
-
product
6 Channel Signal Conditioner & Data Acquisition Module
DP-cPCI-1197
DP-cPCI-1197 is a high-resolution signal-conditioning module that amplifies the signals from full-bridge based transducers. This signal-conditioning module is available on a cPCI module form factor. This module has four gain settings to accommodate a wide variety of sensor output voltages. In addition, this module has an adjustable excitation voltage to accommodate transducer excitation requirements.A high resolution sigma-delta ADC and variable gain amplifier forms the core of the signal conditioning system. Direct digital conversion and digital isolation ensures a better signal integrity in comparison with the conventional analog system.
-
product
8/16-CH 16-Bit Analog Output Cards
PCI-6208/6216 Series
ADLINK PCI-6208/6216 series are 8 or 16-CH, 16-bit, analog output cards. The PCI-6208V-GL offers 8 voltage outputs with ±10 V range, featuring 15-bit monotonicity and 10 V/μs slew rate. The on-board analog switches minimize the power-on glitches. PCI-6216V expands the voltage output channels to a total of 16 for higher analog output density requirements. In addition to the voltage output functions, the PCI-6208A features 8 current outputs with ranges of 0-20 mA, 4-20 mA, and 5-25 mA. The daughter board EXP-8A provides high-quality voltage to current transducers. The PCI-6208A device is capable of delivering 14-bit monotonicity with 1.3 mA/μs slew rate. ADLINK PCI-6208 series devices provide high-resolution, high-density analog output functionalities and are suitable for ATE, signal generation, industrial process control, servo control and other industrial control applications.
-
product
ADC DAC Module
ZET 210
ZET 210 ADC DAC module is used for constant and alternating voltage signals digital processing and parameters control (the signals are retrieved from various primary transducers). Digital and analog outputs can be used within the scope of actuating units control systems.
-
product
Amplifier
AC-100
The voltage amplifier for connecting piezoelectric acceleration meters, microphones, and other primary voltage output transducers to FFT spectrum analyzers with the IEPE standard current output (ZET 017-U2, ZET 017-U8, A19-U2).
-
product
Analog Input Products
Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.
-
product
Analog Output Data Acquisition (DAQ) Products
Analog Output boards are useful when you need an output where the condition is not just an on or off state. Analog Output boards convert digital values generated by software into the analog voltage or current signals required for controlling frequency inverters, valves, sliders, brightness of lights, or things controlled by motors and other mechnical transducers.
-
product
Bolt Extensometers for Proof Load Testing
Model 3565
Jinan Testing Equipment IE Corporation
The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Bridge Amplifier
90376
This miniature, on-board, transducer amplifier is capable of supplying excitation voltage and amplifying millivolt signals from strain gage based transducers.
-
product
Carrier Demodulator with LED Display
CD23/223
The CD23 and CD223 Digital Transducer Indicators are designed for use with variable reluctance and differential transformer transducers. The CD23 accepts input from a single transducer, and the CD223 accepts two switch-selectable inputs, with Zero and Span controls for each input. The indicators provide 5 Vrms, 5 kHz carrier excitation voltage to the transducer(s) and solid state circuitry to amplify, demodulate and filter the transducer output signals. A 3 1/2 digit front panel display is standard, with a 4 1/2 digit display optionally available.
-
product
Charge Amplifier
ZET 440
Charge amplifier ZET 440 for piezoelectric detectors is intended for:*amplification and conversion of output signals of primary piezoelectric transducers with charge output;*amplification and conversion of output signals of primary transducers with the IEPE type in-built electronics to voltage;*gain ratios: 1, 10, 100;*LPF: 0.1, 1, 10 Hz
-
product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
product
Circuit Breaker Analyzers & Timers
CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.
-
product
Complete Field Meter Site Testing Solution
7 Series
We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.